考虑地基辐射阻尼的灯泡贯流泵房水力振动分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
根据测点的脉动压力时程,构造整个流道的脉动压力场,通过三维有限元数值模拟对淮阴三站泵房进行了水力振动时程分析,计算了新型的灯泡贯流泵房的动力响应。与常规无质量地基模型的计算结果作对比,考虑地基辐射阻尼会使泵房的动力响应值最大降低50%左右,地基辐射阻尼对淮阴三站动力响应的影响比较显著。同时,根据相关控制标准,对泵房振动进行评价,为工程抗振设计提供依据。
On the basis of the pulsating pressure of the measuring locations,the pulsating pressure field of the whole flow passage is structured.A dynamic time-history analysis of pump-house of Huaiyinsanzhan Pumping Station caused by the flow is made to calculate the dynamic response of bulb tubular pump-house.Compared with the conventional method of fixed boundary with no weight foundation,the value of dynamic response decreases by about 50% at the foundation radiation damping,and the influence of the factor is very prominent on the dynamic response of Huaiyinsanzhan Pumping Station.At the same time,the results are evaluated based on control standards,which provide evidence for anti-vibration of projects.
引文
[1]马震岳,董毓新.水电站机组及厂房振动的研究与治理[M].北京:中国水利水电出版社,2004.
    [2]马震岳,陈婧,刘志明,等.三峡水电站主厂房振动分析[J].三峡大学学报,2004,26(2):111-115.
    [3]欧阳金惠,陈厚群,李德玉.三峡电站厂房结构振动计算与试验研究[J].水利学报,2005,36(4):484-490.
    [4]贺向丽,李同春.无限域中的动力人工边界[J].水利水电科技进展,2005,25(3):64-67.
    [5]Deeks AJ,Randolph MF.Axisymmetric ti me-domain transmit-ting boundaries[J].Journal of Engineering Mechanics 1994,120(1):25-42.
    [6]贺向丽,李同春.粘-弹性人工边界在重力坝动力分析中的应用[J].水电能源科学,2006,24(1):30-32.
    [7]吴健,金峰,张楚汉,等.无限地基辐射阻尼对溪洛渡拱坝地震响应的影响[J].岩土工程学报,2002,24(6):716-719.
    [8]GB_T50265-97,泵站设计规范[S].
    [9]陈婧,马震岳,刘志明,等.水轮机压力脉动诱发厂房振动分析[J].水力发电,2004,30(5):24-27.
    [10]欧阳金惠,陈厚群,张超然,等.156 m水位下三峡水电站15号机组厂房结构的振动安全研究[J].水利水电技术,2007,38(9):48-51.
    [11]李敏达.龙口泵站出水压力钢管振动处理[J].中国农村水利水电,2007,(6):106-107.