水电站厂房振动和裂缝问题的研究与治理
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
针对大中型水电站出现的若干振动问题实例,以及个别厂房混凝土结构出现裂缝等不利情况,介绍并探讨了厂房振动的诱因、特征和解决途径等问题,旨在为水电站厂房的抗振设计和运行管理提供一些参考。
In allusion to some cases of the vibration problems occurred in mid-large sized hydropower stations and the unfavorable phenomena of crackings happened within concrete structures of some powerhouses,the causations,characters,solving ways,etc.of the vibration of powerhouse are described and discussed herein,so as to provide some references for the anti-vibration design and the operation management of the powerhouse for hydropower station.
引文
[1]马震岳,董毓新.水轮发电机组动力学[M].大连:大连理工大学出版社,2003.
    [2]马震岳,董毓新.水电站机组与厂房振动的研究与治理[M].北京:中国水利水电出版社,2004.
    [3]白国良,李红星,陈爱国,等.厂房动力特性测试及加固效果评估[J].世界地震工程,2003,19(2):51-57.
    [4]钟振宇,陈龙珠,王柏生.阻尼夹层板的振动特性分析[J].土木工程学报,1998,31(3):41-46.
    [5]奚铭.工程振动问题的治理及实例[J].工业建筑,2005,35(S1):942-944.
    [6]刘纪陆.单层工业厂房横向结构的抗震加固[J].四川建筑科学研究,2000,26(3):20-22.
    [7]马震岳,董毓新,沈成能,等.红石水电站厂房的机组诱发振动及抗振加固研究[J].水力发电学报,2002,(1):28-36.
    [8]唐培甲.岩滩水电站水轮机振动问题的研究[J].红水河,2000,19(3):59-62.
    [9]沈可,张仲卿,梁政.岩滩水电站厂房水力振动计算[J].水电能源科学,2003,21(1):73-75.
    [10]Steven N Roy,Kevin P Snyder,Charles D Wagner,et al.Spillway-Powerhouse Interaction at Chickamauga Dam[A].Proceedings ofWaterpower’97[C].Atlanta.1997.294-303.
    [11]杜晓京.地下厂房机组支撑结构振动观测与分析[J].水力发电,1999,(2):27-30.
    [12]练继建,王海军,王日宣,等.大型水电站厂房上部结构振动特性研究[J].水利水电技术,2005,36(7):43-48.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心