预应力混凝土框架抗震性能拟静力试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
通过一榀多层单跨有粘结预应力混凝土框架在低周反复水平荷载下的拟静力试验,进行了预应力混凝土框架的破坏形态、位移延性、刚度退化、耗能能力等抗震性能的研究。结果表明,经合理设计的预应力混凝土框架能依次形成多个塑性铰,结构具有较好的延性和耗能能力,锚具具有较好的工作性能,分析结果为预应力混凝土框架在地震区的工业应用提供参考。
Based on the pseudo-static test of the single-span,multi-story,bonded prestressed concrete frame under the horizontal reversed cyclic loads,the seismic performance of the prestressed concrete frame is studied,including damage state,ductility factor,stiffness degradation,the energy dissipation etc.The research proves that the frame could have several plastic hinges successively,the ductility and energy-dissipating capability of prestressed concrete frame designed properly is well.The working performance of anchor device is also satisfactory.The results could be reference for the industrial application of prestressed concrete frame in seismic district.
引文
[1]陈红媛,房贞政,林飞.无粘结部分预应力混凝土框架抗震性能试验研究[J].地震工程与工程振动,2002,22(2):60-65.
    [2]孟少平,周明华,朱广富.预应力混凝土框架结构抗震能力的试验研究[J].工业建筑,2002,32(10):17-22.
    [3]中国建筑科学研究院.GB50152—92混凝土结构试验方法标准[S].北京:中国建筑工业出版社,1992.
    [4]王红囡,周德源,吴晓涵.预应力混凝土框架结构抗震性能伪静力试验研究[J].建筑结构,2005,35(5):74-76.
    [5]中国建筑科学研究院.JGJ 101—96建筑抗震试验方法规程[S].北京:中国建筑工业出版社,1997.