为与《尿素造粒塔设计规定》进行对比,对某尿素造粒塔进行了多维地震反应时程分析,以全面了解其抗震性能,分析结果表明:规范规定的地震作用计算方法偏于保守,时程分析法可以得到较好的计算效果。
With the Urea Prilling Tower Design Requirements for comparison,it did time-history analysis for some urea prilling tower with multi-dimensional seismic input to fully understand the seismic performance.The results showed that the normative role of the provisions of the seismic calculation is conservative,time-history analysis can get better calculated results.