既有强梁弱柱钢筋混凝土框架抗震加固方法研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
在调研国外文献及相关试验数据的基础上,根据我国规范,提出三种对延性较差的强梁弱柱钢筋混凝土框架结构切实可行的抗震加固方法:扩大柱截面法、体外刚性支撑体系法和抑制屈曲支撑体系法。并提出针对国内类似结构的设计建议及构造措施,为其加固设计及改造提供参考。
Based on calculation and analysis rules of Chinese codes,three seismic reinforcement methods,which are column enlargement method,normal rigid brace method and buckling restrained brace method,for the strong beam-weak column RC frame were investigated according to the relative foreign papers and tests.Some useful design suggestions and constructional details were given for similar structure system.
引文
1]肖从真.汶川地震震害调查与思考[J].建筑结构,2008,38(7):21-24.
    2]傅学怡.汶川、台湾建筑震害启示-改进规范的几点建议[J].建筑结构,2008,38(7):15-16.
    3]BUSH T D,JONES E A,JIRSA J O.Behavior of RCframe strengthened using structural steel bracing[J].Journal of Structural Engineering,1991,117(4):1115-1226.
    4]BUSH T D,JR,TALTON C R,JIRSA J O.Behavior ofa structure strengthened using reinforced concrete piers[J].Journal of Structural Engineering,1990,87(5):557-563.
    5]GB50010—2002混凝土结构设计规范[S].北京:中国建筑工业出版社,2002.
    6]GB50017—2003钢结构设计规范[S].北京:中国计划出版社,2003.
    7]GB50011—2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
    8]李国强,孙飞飞,宫海,等.TJ型屈曲约束支撑工程应用分析[J].建筑结构,2009,39(S1):163.
    9]GB50367—2006混凝土结构加固设计规范[S].北京:中国建筑工业出版社,2006.