淮北市某中学教学楼检测与抗震鉴定
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
汶川地震造成许多中小学校舍倒塌,校舍安全引起学术界和工程界的普遍关注。本文以淮北市某中学教学楼为例,介绍了该教学楼抗震现状。根据对该教学楼的现场检测、抗震调查和鉴定分析,提出几点中小学教学楼抗震鉴定和加固设计的建议。
Wenchuan earthquake caused collapse of many local primary and secondary schools.Building safety attracted universal attention from academia and engineering.This paper took a middle school building in Huaibei as an example to introduce its seismic status.According to the inspection,seismic investigation and identification of this building,some suggestions for seismic appraisal and strengthening design of the primary and secondary school buildings were also proposed.
引文
1 GB50011-2001,建筑抗震设计规范(2008版)[S].
    2 GB50023-2009,建筑抗震鉴定标准[S].
    3邵莲芬,等.从汶川地震之影响谈我国“中小学教学楼的加固与设计”[J].工程抗震与加固改造,2008(4):81-82.
    4姚秋来.5.12汶川特大地震都江堰灾区震害调查[J].工程抗震与加固改造,2008(4):12-23.
    5 GB50009-2001,建筑结构荷载规范[S].