预应力混凝土管桩斜截面抗剪承载力试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
预应力混凝土管桩的斜截面抗剪承载力是其主要承载指标,但是由于相关研究成果较少,国内常引用日本的标准公式,难以精确地评价其性能,而且对管桩斜截面抗震性能未见报道。现分析管桩抗剪承载力的影响因素,对调整配置参数的专用试件做抗剪试验,全过程揭示了管桩的抗剪破坏形态。试验表明,管桩箍筋配筋率、混凝土强度、有效预压应力是影响其斜截面抗剪强度的主要因素,在土质地基中正常受力状态的管桩均为受弯破坏,提出了不同条件下的管桩抗剪承载力的计算方法,并提出了管桩抗震验算的综合修正公式。
Oblique section shear bearing capacity is a key bearing index for pre-stressed concrete pipe piles.As lack of relevant study,Japanese formula is usually used in China,which cannot appraise the performance of piles exactly;and reports on oblique section seismic performance of the piles are even not found.After analyzing influence factors of shear bearing capacity and shear test on specimens by special configured parameters,the whole shear failure process for pipe piles was enclosed.The results show that loop bar percentage,concrete strength and effective prestress are main factors influencing oblique section shear strength of pipe piles and it is all bending failure under normal stress state in soil ground.The calculating method for shear bearing capacity of pipe piles under various conditions and comprehensive correction formula for seismic checking are put forward.
引文
[1]徐至钧,李智宇.预应力混凝土管桩设计施工及应用实例[M].北京:中国建筑工业出版社,2009.
    [2]吕志涛,周明华,陈友文.环形截面钢筋混凝土受弯构件的抗剪强度试验研究[J].南京工学院学报,1980,3(3):26-31.
    [3]吕志涛,石平府,周燕勤.圆形、环形截面钢筋混凝土受弯构件的抗剪承载力的试验研究[J].建筑结构学报,1995,16(3):13-20.
    [4]凌应轩,李建宏,黄晨.预应力混凝土管桩抗剪承载力计算方法[J].工程与建设,2001,29(1):73-75.
    [5]夏春,董腾飞.预应力高性能混凝土管桩螺旋箍筋受力研究[J].土工基础,2004,18(2):46-48.
    [6]刘永超.预应力混凝土管桩结构性能研究及新桩型开发[D].天津:天津大学,2009.
    [7]《汶川地震建筑震害与灾后重建分析报告》编委会.汶川地震建筑震害与灾后重建分析报告[M].北京:中国建筑工业出版社,2008.
    [8]张志强.混凝土管桩在昆明8度抗震区的设计和应用[J].建筑结构,2004,34(4):45-47.
    [9]阮起楠.地震区预应力混凝土管桩设计探讨[J].混凝土与水泥制品,2000,6(4):23-28.
    [10]富文权.预应力混凝土管桩的抗震问题[J].混凝土与水泥制品,1995,10(1):34-38.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心