摘要
对一并联复合隔震结构模型进行了振动台试验研究,通过逐渐增加摩擦滑板的数量来调整隔震层摩擦承压比的大小。分析了复合隔震体系不同摩擦承压比对隔震层滞回特性、基底剪力系数以及复合隔震体系非线性性能的影响。试验结果表明:复合隔震结构的非线性特性与摩擦承压比的大小及地震烈度大小有关,在合理的摩擦承压比取值范围内复合隔震结构具有良好的隔震性能。
A modle of parallel composite isolation,which the friction pressure ratio of isotation is changed by increasing the number of friction skateboarding,is tested to simulate the earthquake on shaking table in this paper.The influences of the hysteresis characeeristics,basal shear coefficient and the nonlinear properties of composite isolation system in different friction pressure ratio are analyzed.Experiment results show: the nonlinear properties of composite isolation system depend on friction pressure ratio and earthquake fore,and composite isolation system can provide good isolation performance in reasonable friction pressure ratio.
引文
[1]杨树标.砌体复合隔震体系研究[J].工程力学,1999(增刊):615Yang Shu-biao.Research on masonry composite isolationsystem[J].Engineering Mechanics,1999(supplement):615(in Chinese)
    [2]杨树标,贾剑辉,申彦利.复合隔震结构的研究与应用[A].防震减灾工程研究与进展[C],北京:科学技术出版社,2005,240~244Yang Shu-biao,Jia Jian-hui,Shen Yan-li.The Researchand Application of Composite Isolation Structure[A].TheResearch and Progress of Earthquake Prevention andDisaster Reduction Engineering[C],Beijing:ScienceTechnology Press,2005,240~244(in Chinese)
    [3]杨树标,周书敬.砌体复合隔震结构设计方案的合理选择[J].建筑结构,2001,31(3):64~66Yang Shu-biao,Zhou Shu-jing.The reasonably selectingthe design scheme of composite seismic isolated masonrystructure[J].Building Structure,2001,31(3):64~66(in Chinese)
    [4]杨树标.砌体并联复合隔震体系的隔震性能研究[J].工业建筑,2000,30(12):15~17Yang Shu-biao.Study on Isolation Performance of ParallelComposite Isolation in Bricking-structure[J].IndustrialConstruction,2000,30(12):15~17(in Chinese)
    [5]杨树标,李振宁.几种隔震体系的地震反应分析[J].特种结构,2001,18(1):36~38.Yang Shu-biao,Li Zhen-ning.Analyse on The SeismicResponse of Several Base Isolated Structure System[J].Special Structures,2001,18(1):36~38(in Chinese)
    [6]日本建筑学会著.刘文光译.隔震结构设计[M].北京:地震出版社,2006.Architectural Institute of Japan.Liu Wen-guang(translate).Recommendation for the Design of BaseIsolated Buildings[M].Beijing:Seismic Press,2006

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心