高层结构设置TMD阻尼器减震效果
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
依据拉格朗日方程推导出了高层结构设置TMD减震阻尼器系统的运动方程,并根据龙格库塔法运用MATLAB编程求解。结果表明,设置TMD阻尼器以后,结构的位移、速度、弯矩等都有明显减小。该减震系统具有良好的减震性能,特别是当,M/m=1,μ=0.01,K0=104kN/m,C0=105kN/m.s时,减震效果最佳。
A theoretical analyzing approach about a novel tuned mass damper system,on high-rise building,was derived according to Lagrange Equation.The solution was programmed with MTALAB software based on the Longe-Kuta method.Computation results show that the displacement,the velocity,and the moment of the highest point were significantly decreased with this system.The system will exhibit the best efficiency with the slip friction factor being 0.01,the spring coefficient 10000kN/m,the damping coefficient 100000 kN/m·s and the tuned mass 1.0 times of the mass of per length of the structure.
引文
[1]周福霖.工程结构减震控制[M].北京:地震出版社,1997.
    [2]Sladek J R,Klinger R E.Effect of tuned mass dampers on seismic response[J].J.Struct.Div,1983,109:2004-2009.
    [3]J.P.T.Yao.Concept of Structure Control of Structure Division[J].ASCE 98.1567-1574(1972).
    [4]潘琴存.摩擦摆TMD减震结构的动力分析与试验研究[D].华中科技大学,2006.
    [5]汪源浩,沈小璞,王建国.超高层建筑结构的减震控制技术与抗震设计要点[J].合肥工业大学学报(自然科学版),2006,29(3).
    [6]邹经湘,于开平.结构动力学[M].哈尔滨:哈尔滨工业大学出版社,2009.4.
    [7]葛楠,苏幼坡,王兴国等.竖向刚度对FPS滑移摩擦摆系统隔震性能影响研究[J].工程抗震与加固改造,2010,32(4),20-25.
    [8]李庆扬,王超能,易大义.数值分析[M].北京:清华大学出版社,2008.12.
    [9]原思聪.MATLAB语言与应用技术[M].北京:国防工业出版社,2011.8.
    [10]Satish Naga rajaiah,Ertan Sonmez.Structures with seismictive variable stiffness single/Multiple tuned mass dampers[J].Journal of Structural En-gineering,2007,133(1):67-77.