钢框架与节能复合墙板连接方式的试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
钢框架与复合墙板通过一定方式进行连接,形成一种协同作用的结构体系,这种体系具有良好的抗侧力性能。为了研究不同连接方式对结构抗侧力性能及滞回性能产生的影响,设计了墙板与钢框架梁连接方式和柱连接方式两榀足尺模型,并对其进行了水平循环加载试验。研究结果表明:这种结构体系能有效提高结构的极限承载力与抗侧刚度;相比梁连接方式,柱连接方式表现出更好的延性与耗能能力,结构的整体性与可靠性也较好,其抗震性能优于梁连接方式。
Steel frame and energy-saving composite panel can be connected in specified arrangements to form a coordinating structural system,which has the good property of lateral resistance.In order to study different effects of lateral resistance and hysteresis characteristic between two arrangements,two full-scale models with a conducting low-cycle reciprocating loading test were designed,which were called beam connection and column connection.It was proved that both systems could effectively improve the ultimate bearing capacity and lateral stiffness.Compared with the beam connection,the column connection showed a better ductility,energy dissipation,structural integrity and reliability.In addition,the column connection could give better seismic performance than the beam connection.
引文
[1]李永华.CL复合墙板混凝土双面现浇施工技术[J].山西科技,2005(1):126-129.LI Yonghua.The technology of tw o-sided cast of CL com-plex w allboard concrete[J].Shanxi Science and Technolo-gy,2005(1):126-129.
    [2]李渤生,李金文,侯和涛.钢结构住宅节能复合外墙板的应用研究[J].钢结构,2007,22(11):9-12.LI Bosheng,LI Jinw en,HOU Hetao.Study on energy-saving composite panel in steel residence houses[J].Steel Construction,2007,22(11):9-12.
    [3]孙维理,刘宜靖.一种优良的节能抗震建筑体系———钢结构+ALC板围护结构[J].墙材革新与建筑节能,2002(9):35-38.SUN Weili,LIU Yijing.A good energy-saving seismicbuilding system-steel structure+ALC palisade structure[J].Walling Material Innouation and Energy Conseru-ation of Buildings,2002(9):35-38.
    [4]闫复华,孔德超,侯和涛.CL结构体系设计和施工中存在的问题与改进措施[J].新型建筑材料,2008(5):24-26.YAN Fuhua,KONG Dechao,HOU Hetao.Problems indesign and construction of CL structure system and im-provement[J].New Building Materials,2008(5):24-26.
    [5]中国建筑技术研究院.JGJ99-98高层民用建筑钢结构技术规程[S].北京:中国建筑工业出版社,1998.
    [6]侯和涛,邱灿星,李国强.钢框架结构与墙体(板)共同作用的研究[J].钢结构,2010,4(25):25-28.HOU Hetao,QIU Canxing,LI Guoqiang.Research onthe interaction betw een the steel frames and the infilledw alls(panels)[J].Steel Construction,2010,4(25):25-28.
    [7]李国强,王城.外挂式和内嵌式ALC墙板钢框架结构的滞回性能试验研究[J].钢结构,2005,20(1):52-56.LI Guoqiang,WANG Cheng.The hysterestic behavior ofsteel frames w ith ALC out-hung and in-filled w alls[J].Steel Construction,2005,20(1):52-56.
    [8]李国强,方明霁,陆烨.钢结构建筑轻质砂加气混凝土墙体的抗震性能试验研究[J].地震工程与工振动,2005,25(2):82-87.LI Guoqiang,FANG Qiming,LU Ye.Experimental re-search on seismic behavior of steel frames w ith ALC ex-ternal w all panels and masonry w all[J].Earthquake Engi-neering and Engineering Vibration,2005,25(2):82-87.
    [9]李国强,方明霁,刘宜靖,等.钢结构住宅体系加气混凝土外墙板抗震性能试验研究[J].土木工程学报,2005,38(10):27-31.LI Guoqiang,FANG Mingji,LIU Yijing,et al.An ex-perimental study on the seismic behavior of ALC externalw all panels in steel frames[J].China Civil EngineeringJournal,2005,38(10):27-31.
    [10]李国强,赵欣,孙飞飞,等.钢结构住宅体系墙板及墙板节点足尺模型振动台试验研究[J].地震工程与工程振动,2003,23(1):64-70.LI Guoqiang,ZHAO Xin,SUN Feifei,et al.Shakingtable study on a full scale model of w all panels and theirconnections of steel frame residential building systems[J].Earthquake Engineering and Engineering Vibration,2003,23(1):64-70.
    [11]De MATTEIS G.Diaphragm action of sandwich panelsin pin-jointed steel structures:a seismic study[J].Jour-nal of Earthquake Engineering,2000,4(3):251-275.
    [12]De MATTEIS G.Effect of lightweight cladding panelson the seismic performance of moment resisting steelframes[J].Engineering Structures,2005(27):1662-1676.
    [13]Applied Technology Council.ATC-24 guidelines for cy-clic seismic testing of components of steel structures[S].Redwood City(CA):Applied Technology Coun-cil,1992.
    [14]王维维,郭耀杰,王小波.钢管混凝土柱-梁节点荷载-位移滞回曲线试验研究[J].钢结构工程研究,2004(S):187-189.WANG Weiw ei,GUO Yaojie,WANG Xiaobo.Experi-mental research on hysteretic behavior of concrete filledtubular column to beam connections[J].Steel Engineer-ing,2004(S):187-189.
    [15]唐九如.钢筋混凝土框架节点抗震[M].南京:东南大学出版社,1989.
    [16]FU Jimot T,INAI E,KAI M,et al.Behavior of beam-to-column connection of CFT column system[C/OL]//The 12th World Conference on Earthquake Engineering.2000[2011-04-08].http://w w w.iitk.ac.in/nicee/w cee/artical/2197.pdf.
    [17]李帼昌,姜杰,蒋奇峰,等.低周往复荷载作用下钢管煤矸石混凝土梁柱节点抗震性能的有限元分析[J].沈阳建筑大学学报:自然科学版,2011,27(2):260-265.LI Guochang,JIANG Jie,JIANG Qifeng,et al.Non-linear FEM analysis on seismic performance of beam togangue concrete filled steel tubular column joints underreversed low cyclic loads[J].Journal of ShenyangJianzhu University:Natural Science,2011,27(2):260-265.
    [18]王天稳.土木工程结构试验[M].武汉:武汉理工大学出版社,2007.
    [19]中国建筑科学研究院.GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
    [20]中国建筑科学研究院.JGJ101-96建筑抗震试验方法规程[S].北京:中国建筑工业出版社,1997.