水用检波器快速测试仪的设计与实现
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
为检测水用检波器在固定频率的灵敏度,以便快速准确地确定检波器的好坏,设计了水用检波器快速测试仪.测试仪主要由信号源模块、功率放大模块、数据采集模块和显示模块等部分组成,以ATmega128为主控芯片,利用A/D转换芯片AD7663进行数据采集,将检波器的灵敏度实时地显示在液晶屏上,以便观察.测试结果表明,快速测试仪的最大偏差为0.5,μV/Pa,测试结果与标称值的平均相对误差为0.93%.可见,快速测试仪的测试结果准确,且重复性较好.
A hydrophone quick tester was designed to detect the sensitivity of hydrophone at a certain frequency so as to ascertain its performance quickly.The quick tester mainly consists of a signal source module,a power amplifier module,a data acquisition module and a display module.ATmega128 was used as the main control chip of the quick tester,A/D converter chip AD7663 was used to design the data capture circuit,and the sensitivity can be displayed on the LCD real-time,so it is easy to observe.Test results show that the maximum deviation is 0.5,μV/Pa,and the average relative error of the test results against the nominal value is 0.93%.The testing result is accurate and repeatable.
引文
[1]付小宁.地震检波器参数测试的现状及动向[J].石油工业技术监督,2000,16(3):30-31.
    [2]易碧金.地震仪器中地震道检波器的测试原理和方法[J].物探装备,1998,8(2):6-9.
    [3]孙宏军,郭宝龙,程霖.基于ARM的检波器特性测量仪设计与实现[J].国外电子元器件,2007(10):6-9.
    [4]李淑清,赵耀,沈时强,等.海洋检波器性能测试仪信号源的设计[J].自动化与仪表,2009,24(1):9-12.
    [5]李晶皎,刘天华,丁言镁.液晶显示器的C语言程序设计[M].北京:科学出版社,2005:73.
    [6]陈冬云,杜敬仓,任柯燕.ATmega128单片机原理与开发指导[M].北京:机械工业出版社,2005:292-304.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心