模型结构的压电摩擦阻尼减振控制试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
在压电摩擦阻尼器力学性能试验的基础上,对一安装有压电摩擦阻尼器的模型结构进行了地震模拟振动台试验研究。利用MATLAB/Simulink软件平台和dSPACE软硬件资源,建立了压电摩擦阻尼结构控制系统的仿真模型,采用快速控制原型技术对模型结构进行了地震反应振动台试验。通过振动台试验验证了地震作用下提出的压电摩擦阻尼器和以速度响应为输入的模糊控制方法调节阻尼器控制力的有效性。试验结果表明,提出的压电摩擦阻尼器能够根据结构的响应实时调整阻尼器的摩擦力,可以有效减小模型结构在地震作用下的位移反应和加速度反应。
Based on performance tests of a piezoelectric friction damper,a series of shake table tests for a model structure were carried out with a piezoelectric friction damper under various earthquakes.The simulation model of the structure with the piezoelectric friction damper was established by using MATLAB/Simulink software platform and software/hardware resources of dSPACE(digital signal processing and control engineering).The shake table tests were implemented by using rapid control prototype technology.The a seismic efficiencies of the designed piezoelectric friction damper and the proposed velocity-input fuzzy control strategy were both evaluated.Experimental results indicated that the designed piezoelectric friction damper can adjust its damping force according to the structural responses with the proposed control method in real-time and effectively suppress the structural responses under earthquake excitations.
引文
[1]杨飏,欧进萍,刘光聪.T型压电变摩擦阻尼器性能试验与分析[J].压电与声光,2005,27(5):580-582.
    [2]杨飏,欧进萍.压电变摩擦阻尼器减振结构的数值分析[J].振动与冲击,2005,24(6):1-4.
    [3]胡卫兵,王骏涛.压电摩擦阻尼隔震结构地震响应及控制分析[J].振动与冲击,2007,26(2):79-83.
    [4]张永兵,张永申,李双蓓,等.3层基准建筑非线性地震反应的智能控制[J].土木建筑与环境工程,2009,31(1):49-54.
    [5]张永兵,秦荣,李双蓓,等.压电变摩擦阻尼器对高层建筑非线性地震反应的模糊控制算法[J].振动与冲击,2008,27(11):142-146.
    [6]亓兴军,李小军,唐晖.曲线桥梁弯扭耦合减震半主动控制分析[J].公路交通科技,2006,23(9):54-57.
    [7]Chen G D,Garrett G T,Chen C Q,et al.Piezoelectricfriction dampers for earthquake mitigation of buildings:design,fabrication,and characterization[J].StructuralEngineering and Mechanics,2004,17(3-4):539-556.
    [8]Chen C Q,Chen G D.Shake table tests of a quarter-scalethree-story building model with piezoelectric friction dampers[J].Structural Control and Health Monitoring,2004,11(4):239-257.
    [9]Ng L C,Xu Y L.Semi-active control of a building complexwith variable friction dampers[J].Engineering Structures,2007,29(6):1209-1225.
    [10]Xu Y L,Ng C L.Seismic protection of a building complexusing variable friction damper:experimental investigation.Journal of Engineering Mechanics,2008,134(8):637-649.
    [11]赵大海,李宏男.压电摩擦阻尼器的试验研究[J].压电与声光,2009,31(1):60-62.
    [12]赵大海,李宏男.基于T-S型模糊逻辑的半主动摩擦阻尼器对非线性结构的振动控制[J].工程力学,2007,24(12):65-71.