高层钢抗弯框架抗震性能研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
29年前设计及建造的26层91m高的北京长富宫中心饭店采用的是纯钢框架结构。介绍了当时该工程的设计概况,并用现行规范及软件对结构做了计算分析,验证了结构可以满足现行规范的要求。同时对同一建筑采用的三种结构形式(钢框架结构、钢框架-支撑结构与钢框架-混凝土剪力墙结构)均进行了弹性及弹塑性分析,对比表明钢抗弯框架具有较好的延性及抗震性能。最后对钢抗弯框架适用的高度范围及加强抗震框架的抗震性能进行了探讨。
Beijing Chang Fu Gong Center Hotel,bulit 29 years ago,is a 26-storey steel frame structure with 91m in height.The overview design at that time was given and the structure was analyzed with current specifications and software,which verified that the structure can meet the current specification requirements.Three structural systems of the same building,including steel frame,steel frame-braced structure and steel frame-concrete shear wall structure,were compared using elastic and elastic-plastic analysis methods.Results show that steel moment-resisting frame structure has better ductility and seismic performance.Finally applicable height range of steel moment-resisting frame structure and reinforcement measures of the frame's seismic performance were discussed.
引文
[1]崔鸿超,王柱云.长富宫中心高层钢结构设计[J].建筑技术,1989,29(12):6-13.
    [2]王康强.长富宫中心高层钢结构安装[J].建筑技术,1989,29(12):16-22.
    [3]钱稼茹,方郑华,崔鸿超.长富宫高层钢结构在罕遇地震时的安全检验[J].建筑结构学报1992,13(6):2-10.
    [4]胡庆昌,孙金,郑琪.建筑结构抗震减震与连续倒塌控制[M].北京:中国建筑工业出版社,2007.
    [5]崔鸿超,王桂云,王暐,等.钢框架梁、柱节点在反复循环荷载作用下的试验研究[J].建筑结构学报,1990,11(1):52-66.