210m高烟囱爆破拆除触地振动控制措施研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
南昌电厂210m高钢筋混凝土烟囱爆破拆除工程,采用在烟囱根部开凿拱形超大导向窗、倾倒方向设置触地危害防护体系等措施进行触地振动控制。振动监测分析和实际爆破效果表明,预开拱形超大导向窗更有利于烟囱根部解体,且触地破碎效果更好;各项减振措施使得触地冲击速度减小到计算值的21%~71%,减振效果显著,相关减振措施可为类似工程提供参考。
The touchdown vibration control measures such as cutting large arc direction-guide window at the root of the chimney and setting the vibration integrated protection system were researched in the blasting demolition project of a 210m-high reinforced concrete chimney in Nanchang power plant.The vibration monitoring analysis and blasting effect showed that cutting large arc guide window was benefit for the disintergration of the chimney root and the touchdown impact velocity could reduce to 21%~71% compared with the calculated value.Thus vibration control measures could provide a reference for the similar directional blasting project.
引文
〔1〕王迪安.79m高烟囱拆除爆破振动与塌落触地振动对比分析[J].工程爆破,2006,12(1):86-89.
    〔2〕张世平,阎晋文.爆破拆除高大建筑物产生的震动危害与减震方法[J].太原理工大学学报,2006,37(6):685-687.
    〔3〕宗琦,汪海波,周胜兵.爆破地震效应的监测和控制技术研究[J].岩石力学与工程学报,2008,27(5):938-945.
    〔4〕褚怀保,余永强,杨小林,等.钢筋混凝土冷却塔爆破拆除控振措施研究[J].河南理工大学学报(自然科学版),2010,29(1):85-87.
    〔5〕中华人民共和国国家标准.爆破安全规程(GB6722-2003)[S].北京:中国标准出版社,2004.
    〔6〕陈德志,丁帮勤.苛刻条件下100m高钢筋混凝土烟囱定向爆破与震动测试[J].工程爆破,2003,9(2):33-35.
    〔7〕罗艾民,林大能,潘果斌.建筑物塌落体触地冲击力计算方法研究[J].西安科技学院学报,22(3):168-271.
    〔8〕李本伟,陈德志,张萍,等.180m高钢筋混凝土烟囱爆破拆除[J].爆破,2011,28(4):57-60.
    〔9〕周家汉.爆破拆除塌落振动速度计算公式的讨论[J].工程爆破,2009,15(1):1-5.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心