碳纤维布补强植筋增层节点抗震性能试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对使用无机锚固材料植筋连接的钢结构加层后的3层框架结构进行了拟静力抗震试验,并同增层节点采用碳纤维布加固补强后的拟静力试验进行对比分析。试验结果表明:使用无机锚固材料植筋连接并进行钢结构加层改造的框架结构具有较好的抗震延性,对增层节点进行碳纤维布补强后结构的整体抗震性能更为优越,塑性铰形成顺序更为合理,从而能够更好地满足加层结构的工程抗震要求。
The quasi-static seismic experiment on a three-adding-story steel frame structure strengthened by planting bar with inorganic anchoring material was carried out and compared with the strengthening method of carbon fiber sheet. The results indicate that the seismic ductility of the adding-story steel frame structure strengthened by planting bar with inorganic anchoring material is well but not better than that of structural joints strengthened by carbon fiber sheet. Structural joints strengthened by carbon fiber sheet have reasonable emerging sequence of plastic hinge and can satisfy the requirements of the engineering seismic performance of adding-story structures well.
引文
[1]JGJ/T 271—2012混凝土结构工程无机材料后锚固技术规程[S].北京:中国建筑工业出版社,2012.
    [2]周新刚,司伟建,李春祥.钢筋混凝土植筋锚固构件受低周反复荷载作用的恢复力特性[J].建筑结构,2002,32(8):38-40.
    [3]李辉,张惠英,杨军.植筋混凝土柱延性和耗能能力的试验研究[J].建筑结构,2005,35(3):18-20.
    [4]邓宗才,钟林杭,张永方,等.植筋钢筋混凝土锚固构件抗震性能试验研究[J].北京工业大学学报:自然科学版,2011,37(5):707-712.
    [5]郭蓉,赵少伟,尹成林.轻钢结构加层中新型节点抗震性能试验研究[J].工程抗震与加固改造,2013,35(3):97-102.
    [6]麻建锁,张涛,王元清,等.钢筋混凝土框架顶部钢结构加层的抗震性能分析[J].地震工程与工程振动,2006,26(3):118-120.
    [7]戴绍斌,杜黎妍.碳纤维布增强混凝土框架抗震性能的有限元分析[J].地震工程与工程振动,2005,25(4):112-115.
    [8]JGJ 101—96建筑抗震试验方法规程[S].北京:中国建筑工业出版社,1996.
    [9]JGJ 145—2013混凝土结构后锚固技术规程[S].北京:中国建筑工业出版社,2013.
    [10]王婷婷.混凝土结构无机锚固材料后锚固植筋粘结锚固性能的研究[D].济南:济南大学,2012.
    [11]梁玉国,鲁晓琳,宋丽娟.无机锚固材料植筋群锚效应试验研究[J].河北工业科技,2013,30(1):31-34.
    [12]CECS 146∶2003碳纤维片材加固混凝土结构技术规程[S].北京:中国计划出版社,2003.
    [13]郭健,何益斌,郦世平,等.基于刚度退化的框架结构受力性能研究[J].湖南大学学报:自然科学版,2007,34(5):20-23.
    [14]王传志,滕智明.钢筋混凝土结构理论[M].北京:中国建筑工业出版社,1985.