广州电视塔直线电机驱动的主动质量阻尼器动力特性研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
针对广州电视塔的振动控制,提出了直线电机驱动的主动质量阻尼器控制装置实现策略,分别进行了多个直线电机驱动的2个阻尼器子系统的指令力、反馈驱动力、实际驱动力、控制系统、软件限速、软件限位,以及2个子系统一致性和时滞的性能实测,提出了多个直线电机驱动单个主动质量阻尼器的纹波推力和综合阻力识别方法及计算公式。实测结果表明:提出的广州电视塔多个直线电机驱动的主动质量阻尼器控制装置实现策略可行,广州电视塔2个阻尼器子系统能稳定地接收指令力与实现指令力,软件限位及限速安全系统工作良好;提出的多个直线电机驱动单个主动质量阻尼器的纹波推力和综合阻力识别方法及计算公式能较好地识别直线电机驱动的主动质量阻尼器动力特性;2个阻尼器子系统能同步工作且时滞较小,满足广州电视塔振动控制的要求。
For the vibration control of the Canton Tower,the implementing strategy of AMD control device driven by multiple linear motors was presented. The performance tests of the directive force,feedback driving force,actual driving force,control system,velocity limitation by software,stroke limitation by software,control-force homogeneity and time lag of subsystem AMD1 and AMD2 control device driven by multiple linear motors were carried out,and the identification method and the calculation formulas of ripple thrust and comprehensive resistance force for AMD control device driven by multiple linear motors were proposed. The results of actual test for AMD control devices driven by multiple linear motors in the Canton Tower show that the implementing strategy of AMD control device for vibration control of the Canton Tower is feasible. Two subsystems AMD1 and AMD2 can receive and achieve driving force and the security system with stroke limitation and velocity limitation by software have outstanding performances.Meanwhile,the identification method and the calculation formulas of ripple thrust and comprehensive resistance force are suitable for identifying the AMD performance,and the subsystem AMD1 and AMD2 can implement the control force synchronously and have very small time delay,which can meet the requirement of vibration control for the Canton Tower.
引文
[1]Spencer B F,Nagarajaiah S.State-of-the-art of structural control[J].Journal of Structural Engineering,ASCE,2003,129(7):845-855.
    [2]Ricciardelli Francesco,David Pizzimenti A,Mattei Massimiliano.Passive and active mass damper control of the response of tall buildings to wind gustiness[J].Engineering Structures,2003,25(9):1199-1209.
    [3]Bani-Hani Khaldoon A.Vibration control of windinduced response of tall buildings with an active tuned mass damper using neural networks[J].Structure Control and Health Monitoring,2007,14(1):83-108.
    [4]Li Luyu,Song Gangbing,Ou Jinping.Hybrid active mass damper(AMD)vibration suppression of nonlinear high-rise structure using fuzzy logic control algorithm under earthquake excitations[J].Structure Control and Health Monitoring,2011,18(6):698-709.
    [5]欧进萍.结构振动控制:主动,半主动和智能控制[M].北京:科学出版社,2003:186-235.
    [6]李惠,铃木祥之,吴波.AMD控制结构地震反应的试验研究[J].振动工程学报,1999,12(2):223-228.(LI Hui,SUZUKI Yoshiyuki,WU Bo.Experimental study on active structural control with AMD[J].Journal of Vibration Engineering,1999,12(2):223-228.(in Chinese))
    [7]张微敬,欧进萍.基于单片机模糊控制器的AMD主动控制试验研究[J].建筑结构学报,2006,27(1):37-42.(ZHANG Weijing,OU Jinping.Experimental study on AMD vibration control based on single-chip fuzzy microcomputer[J].Journal of Building Structures,2006,27(1):37-42.(in Chinese))
    [8]张春魏,欧进萍.电磁驱动AMD系统控制结构地震响应的振动台试验[J].地震工程与工程振动,2006,26(2):104-110.(ZHANG Chunwei,OU Jinping.Shaking table tests of electromagnetic mass damper system for control of structural seismic response[J].Earthquake Engineering and Engineering Vibration,2006,26(2):104-110.(in Chinese))
    [9]李宏男.结构多维减震控制[M].北京:科学出版社,2008:433-450.
    [10]曲春绪,霍林生,李宏男.基于LMI方法的建筑结构AMD容错控制[J].土木工程学报,2013,46(3):1-9.(QU Chunxu,HUO Linsheng,LI Hongnan.Fault tolerant control for civil structures with AMD based on LMI approach[J].China Civil Engineering Journal,2013,46(3):1-9.(in Chinese))
    [11]Zhou Fulin,Tan Ping,Liu Yanhui,et al.Hybrid mass dampers for Canton Tower[J].International Journal on Tall Buildings and Urban Habitat,2012(1):24-29.
    [12]刘彦辉,谭平,周福霖,等.直线电机驱动的AMD性能测试试验研究[J].土木工程学报,2010,43(12):50-56.(LIU Yanhui,TAN Ping,ZHOU Fulin,et al.Experiment investigation of AMD performance driven by linear motor[J].China Civil Engineering Journal,2010,43(12):50-56.(in Chinese))
    [13]刘彦辉.结构主被动混合质量阻尼器控制理论与试验研究[R].北京:北京工业大学,2011:71-94.(LIU Yanhui.Theoretical and experimental study of activepassive hybrid tuned mass damper control system[R].Beijing:Beijing Universtiy of Technology,2011:71-94.(in Chinese))

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心