某错层剪力墙结构的弹塑性时程分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
复杂的超限高层建筑结构需要进行弹塑性分析和计算来验证其是否满足抗震设防要求。以珠海某复杂超限高层建筑工程为背景,对其进行弹塑性时程分析,研究该结构在地震作用下的抗震性能。采用Perform-3D建立三维弹塑性分析模型,并进行了动力时程分析,对结构在地震作用下的整体反应和构件损伤情况进行了分析和评估,用详细的量化指标验证了该结构能够在罕遇地震水平下实现"大震不倒"。结果表明,错层并不会使剪力墙成为结构受剪的薄弱环节。
Inelastic analysis need be used to prove the safety of complex high-rise building structure under rare earthquakes.An inelastic time history analysis of a complex high-rise building with staggered shear-wall located in Zhuhai was carried out,and the seismic performance under different level earthquakes was studied.Perform-3D program was used to build analysis model and carry out time history analysis.The results were concluded in the entire structure response and the damage information of elements,and quantified the damage degree of this structure under rare earthquake,and verified that this structure would not collapse under rare earthquake.The soft shear floor is not formed in the structure.
引文
[1]JGJ3—2002高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2002.
    [2]谢靖中,李国强.错层结构的几点分析[J].建筑科学,2001,17(1):35-37.
    [3]尹保江,龚思礼,程绍革.高层建筑中错层剪力墙结构的试验研究[J].建筑科学,1999,15(6):18-20.
    [4]Perform-3D user guide version4[M].CSI.
    [5]魏琏.建筑结构抗震设计[M].北京:万国学术出版社,1991.
    [6]刘畅,段小廿,魏琏,等.某超限高层结构多程序弹塑性时程分析对比[J].2012,42(11):35-39,18.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心