具有预应力的某型直流滤波电容器载荷分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
直流滤波电容器是直流输变电中的重要设备,以往对其抗震分析未考虑预应力的影响。文中探讨了预应力对直流滤波电容器模态的影响,通过计算说明预应力的存在提高了直流滤波电容器的固有频率,并对直流滤波电容器进行了3种载荷组合分析,得到了放置框架和棒形悬式复合绝缘子应力储备系数。
DC filter capacitor is a key component of DC power transmission and distribution systems. In the past, the studies on the seismic behavior of DC filter capacitor usually neglect the prestressing force.So, in this paper, the model analysis of the DC filter capacitor with prestressing force has been carried out. It is proved that prestressing force improve the natural frequency of the DC filter capacitor through finite element analysis. Then, three kind of load behavior of the DC filter capacitor are studied. In addition, the stress reserve coefficient of the framework andcomposite long rod insulator are obtained.
引文
[1]刘建秋,王亚超,韩文庆.变电站震害分析与抗震措施的研究综述[J].电力建设,2011,32(7):44-50.LIU Jianqiu,WANG Yachao,HAN Wenqing.Review on seismic disaster analysis and aseismatic measures of transformer substation[J].Electric Power Construction,2011,32(7):44-50.
    [2]SAIIDI M.Prestress force effect on vibration frequency of concrete bridges[J].Journal of Structural Engineering-ASCE,1994,120(7):2233-2241.
    [3]SAIID M,HUTCHENS E,GARDELLA D.Bridge prestress losses in dry climate[J].Journal of Bridge EngineeringASCE,1998,3(3):111-116.
    [4]MIYAMOTO A.Behavior of prestrcssed beam strengthened with external tendons[J].Journal of Structural Engineering,2000,126(9):1030-1037.
    [5]HINDI A.Enhancing strength and ductility of post-tensioned segmental box girder bridges[J].ACI Structural Journal,1995,92(1):33-44.
    [6]RAMOS G,APARICIO A C.Ultimate behavior of externally prestressed concrete bridges[J].Structural Engineering International,1995(3):172-177.
    [7]APARICIO A C,RAMOS G.Flexural strength of externally prestressed concrete bridges[J].ACI Structural Journal,1996,93(5):512-523.
    [8]KIM J T,YUN C B,RYU Y S,et al.Identification of prestress-loss in PSC beams using modal information[J].Structural Engineering and Mechanics,2004,17(3/4):467-482.
    [9]刘宏伟,张伟,庄惠平.预加力对梁的动力影响分析[J].黑龙江科技学院学报,2002,12(3):37-39.LIU Hongwei,ZHANG Wei,ZHUANG Huiping.Analysis of dynamic influence from prestressed beam[J].Journal of Heilongjiang Institute of Science and Technology,2002,12(3):37-39.
    [10]楼梦麟,吴京宁.复杂梁动力问题的近似分析方法[J].上海力学,1997,18(3):234-240.LOU Menglin,WU Jingning.Approximate analysis method for complex dynamic problems[J].Chinese Quarterly Mechanics,1997,18(3):234-240.
    [11]楼梦麟,洪婷婷.预应力梁横向振动分析的模态摄动方法[J].工程力学,2006,23(1):107-111.LOU Menglin,HONG Tingting.Mode perturbation method for lateral vibration analysis of prestressed beams[J].Engineering Mechanics,2006,23(1):107-111.
    [12]肖静霆,吴红林.预应力对预应力简支梁自振频率的影响[J].科学技术与工程,2010,10(12):2909-2912.XIAO Jingting,WU Honglin.Prestress force effect on natural frequencies of simply supported prestressed beams[J].Science Technology and Engineering,2010,10(12):2909-2912.
    [13]张耀庭,汪霞利,李瑞鸽.预应力梁固有频率的试验研究[J].华中科技大学学报(自然科学版),2007,35(2):12-15.ZHANG Yaoting,WANG Xiali,LI Ruige.Experimental research on nature frequency of prestressed concrete beams[J].Journal of Huazhong University of Science and Technology(Nature Science),2007,35(2):12-15.
    [14]张耀庭,汪霞利,李瑞鸽.全预应力梁振动频率的理论分析与试验研究[J].工程力学,2007,24(8):116-120.ZHANG Yaoting,WANG Xiali,LI Ruige.Experimental and theoretical research on vibration frequency of fullprestressed concrete beam[J].Engineering Mechanics,2007,24(8):116-120.
    [15]熊学玉,王寿生.体外预应力梁振动特性的分析与研究[J].地震工程与工程振动,2005,25(2):55-61.XIONG Xueyu,WANG Shousheng.Analysis and research of externally prestressed concrete beam vibration behavior[J].Earthquake Engineering and Engineering Vibration,2005,25(2):55-61.
    [16]CLOUGH R W,PENZIEN J.Dynamic of structures[M].Upper Saddle Rive:Prentice Hall,1982.
    [17]金松安,刘朝丰,武胜斌,等.高海拔隔离开关抗震分析研究[J].高压电器,2013,49(10):37-45.JIN Song’an,LIU Chaofeng,WU Shengbin,et al.Study the seismic behavior of disconnector in high altitude area[J].High Voltage Apparatus,2013,49(10):37-45.
    [18]GB/T 13540—2009高压开关设备和控制设备的抗震要求[S].2009.GB/T 13540—2009 Seismic qualification for high-voltage switchgear and controlgear[S].2009.
    [19]GB 50260—2013电力设施抗震设计规范[S].2013.GB 50260—2013 Code for seismic design of electrical installations[S].2013.
    [20]GB 50009—2001建筑结构荷载规范[S].2001.GB 50009—2001 Load Code for the design of building structures[S].2001.