摘要
为了使结构在地震过程中能有效地抗震耗能,提出了一种新型的半主动压电摩擦阻尼器。对压电陶瓷的电压-位移关系进行了理论和试验分析。详细介绍了新设计的压电摩擦阻尼器的构造和工作原理。测试和分析了压电摩擦阻尼器在不同预压力和不同工作压电陶瓷数量下的出力性能和阻尼器的摩擦系数。论述了适用于该阻尼器的模糊控制理论并建立了模糊控策略。最后基于所设计的压电摩擦阻尼器和所形成的模糊控制策略,利用MATLAB软件对一个拟进行振动台试验的输变电塔模型进行了模拟,得到了输变电塔模型在无阻尼器和有阻尼器两种情况下的顶层位移和加速度时程曲线,并对其进行了对比分析。结果表明,所研发的新型压电摩擦阻尼器具有良好的出力性能,使结构能有效地抗御地震灾害。
In order to make effectively the structures can't be destroyed during the earthquake,a new type semiactive of piezoelectric friction damper was designed. The piezoelectric ceramic voltage-displacement relation was analyzed by theoretical and experimental ways. The details of the friction damper'structure and working principle were introduced. The output force performance and damper's friction coefficient of piezoelectric friction damper under different pre-pressures and different numbers of working piezoelectric ceramics were measured and analyzed. The fuzzy control theory suitable to the damper was expounded and corresponding fuzzy control strategy was established.At last,based on the designed piezoelectric friction damper and the fuzzy control strategy,and by use of MATLAB software,a transmission tower model tested on shaking table was simulated,the displacement and acceleration time history curves of transmission tower model under two conditions with and without damper were obtained and compared each other. Results show that the researched and developed new type's piezoelectric firction damper has a good output force performance and can make structure to withstand seismic disaster.
引文
[1]李宏男,阎石.中国结构控制的研究与应用[J].地震工程与工程振动,1999,19(1):107-112.Li Hong-nan,Yan Shi.State-of-the-Art Review:Researches and Applications of Structural Control in China[J].EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION,1999,19(1):107-112.(in Chinese)
    [2]赵大海,李宏男.压电摩擦阻尼器的试验研究[J].压电与声光,2009,31(1):60-62.ZHAO Da-hai,LI Hong-nan.Experimental Investigation of Piezoelectric Friction Damper[J].PIEZOELECTECTRICS&ACOUSTOOPTICS,2009,31(1):60-62.(in Chinese)
    [3]Kamada T.Active Vibration of Frame structures of Shear and Bending Type with Smart Structure Using Piezoelectric Actuator[c].Proceeding of SPIE,1997,3041:75-86.
    [4]CHEN GD,GARRETT GT,CHEN C Q,et al.piezoelectric friction dampers for earthquake mitigation of buildings:design,fabrication,and characterization[J].Structural Engineering and Mechanics,2004,17(3-4):539-556.
    [5]CHEN C Q,CHEN D Q.Shake table tests of a quarter-scale three-storey building model with piezoelectric friction dampers[J].Structural Control and Health Monitoring,2004,11(4):239-257.
    [6]欧进萍.结构振动控制-主动,半主动和智能控制[M].北京:科学出版社.OU Jin-ping.Structural vibration control-active,semi-active and intelligent control[M].Beijing:Science Press.(in Chinese)
    [7]李晓娟,李全禄,谢妙霞,郝淑娟.压电陶瓷材料的发展及其新应用[J]。陕西理工学院院报,2006,22(1):8-12.LI Xiao-juan,LI Quan-lu,XIE Miao-xia,HAO Shu-juan.Piezoelectric ceramic materials development and new applications[J].Journal of Shaanxi University of Technology,2006,22(1):8-12.(in Chinese)
    [8]赵大海,李宏男.基于T-S型模糊逻辑的半主动摩擦阻尼器对非线性结构的振动控制[J].工程力学,2007,24(12):65-71.ZHAO Da-hai,LI Hong-nan.VIBRATION CONTROL OF NONLINEAR STRUCTURE BY SEMI-ACTIVE FRICTION DAMPER BASED ON T-S FUZZY LOGIC[J].ENGINEERING MECHANICS,2007,24(12):65-71.(in Chinese)
    [9]孙增圻.智能控制理论与技术[M].北京:清华大学出版社,1997.SUN ZENG-qin.Intelligent Control Theory and Technology[M].Beijing:Tsinghua University Press,1997.
    [10]He W L,Agrawal A K,Yang J N.Novel simi-active friction controller for linear structures against earthquakes[J].Journal of Structural Engineering,2003,129(7):941-950.