基于粘弹性边界的河床式厂房地震动力响应分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
为分析河床式厂房在地震过程中的动力反应,评价其抗震安全性并找到其抗震薄弱部位及探讨地基辐射阻尼对厂房结构动力响应的影响,运用三维非线性有限元技术,对某厂房在地震过程中的动力反应及抗震安全性进行精确计算分析.其中采用粘弹性边界考虑地基辐射阻尼影响,采用流固耦合的方式考虑水体的作用.计算结果表明:河床式厂房动力响应受顺河向地震作用明显;上部结构动力响应大于下部结构;厂房上游部位动力响应大于靠下游部位:上游排架柱拉、压应力最大达到4.53、-5.58 MPa.同时,将计算结果与无质量地基方案计算结果进行对比得到:考虑地基辐射阻尼能有效降低河床式厂房的地震动力响应,最大降幅可达64.36%.
In order to analyze the seismic response,evaluate the seismic safety,find out the seismic week part during the earthquake,and explore the influence of foundation radiation damping on the dynamic structure,the paper has precisely analyzed the dynamic response and seismic safety of a powerhouse in river channel by adopting 3Dnonlinear finite elements.The viscoelastic boundary has been used to calculate the effect of foundation radiation damping;and the fluid-structure interaction has been used to premeditate the influence of water.The calculation results show that:the ground motion along the river has an obvious effect on the seismic response of the powerhouse;the dynamic response of the upper structure is greater than that of the lower structure;the dynamic response of the upstream part is greater than that of the downstream part;the maximal tensile stress of the upper shelf reaches 4.53 MP and the maximal compression stress is-5.58 MPa.In addition,the comparison between the above calculation result and the calculation result of no mass foundation scheme shows that the seismic response of the powerhouse in river channel can be effectively reduced with a maximum degree of 64.36% by taking the foundation radiation damping into consideration.
引文
[1]顾鹏飞,喻远光.水电站厂房设计[M].北京:水利水电出版社,1987:365.
    [2]宋胜武,蒋峰,陈万涛.汶川地震灾区大中型水电工程真损特征初步分析[J].四川水力发电,2009,28(2):1-8.
    [3]樊锐,陈尧隆,刘武军,等.河床式水电站厂房坝段三维有限元抗震分析[J].水资源与水工程学报,2009,20(5):131-134.
    [4]侯攀,陈尧隆,邓瞻.用ANSYS对水电站厂房坝段进行抗震分析[J].西北水力发电,2005,21(1):44-47.
    [5]何建涛,马怀发,张伯艳,等.黏弹性人工边界地震动输入方法及实现[J].水利学报,2010,41(8):960-969.
    [6]陈平,何蕴龙,陈海霞.地基边界对五嘎冲拱坝地震动力响应的影响[J].武汉大学学报(工学版),2011,44(5):554-559.
    [7]李宏恩,李同春,田景元,等.黏-弹性人工边界在双江口土石坝动力分析中的应用[J].岩土力学,2008,29(S1):189-192.
    [8]李慧君.水电站地下厂房内源振动计算模型和边界条件的研究[D].大连:大连理工大学,2009:51-62.
    [9]韩涛.基于粘弹性边界的地下厂房水力振动研究[D].大连:大连理工大学,2011:30-83.
    [10]刘建峰.水电站地下厂房动力特性研究及地震反应分析[D].大连:大连理工大学,2007:51-58.
    [11]Deeks A J,Randolph M F.Axisymmetric time-domain transmitting boundaries[J].Journal of Engineering Mechanics,ASCE,1994,120(1):25-42.
    [12]刘晶波,吕彦东.结构—地基动力相互作用问题分析的一种直接方法[J].土木工程学报,1998,31(3):55-64.
    [13]杜剑锋,杜修力,韩强,等.外源波动问题数值模拟的一种实现形式[J].工程力学,2007,24(4):52-58.