加固后东北大学建筑系大楼在3·11地震中损坏原因分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
2011年东日本大地震发生后,发现一些抗震加固过的建筑在地震中也遭到了损坏。以一栋位于日本仙台的加固建筑为例,通过实地考察分析总结了其遭受破坏的典型损伤特征。结构在抗震加固前,应对结构的局部损伤和整体性能有准确的把握;抗震加固时应考虑局部加固对结构整体性能的影响,避免因抗震加固造成新的薄弱部位和薄弱层,从而削弱结构的整体性能。抗震加固应从这些受损的建筑物中吸取教训,进一步改进和完善现有的抗震鉴定方法和加固措施。
During the Great East Japan Earthquake,some buildings retrofitted prior to the earthquake were damaged to varying degrees. This paper studies a retrofitted building located at Tohoku University,Japan,which was damaged during the 3 ·11 earthquake. Based on the field investigation,the scenario and characteristics of the structural damage are analyzed,and some related experiment work is summarized. It is necessary to conduct careful investigation of local damage and evaluate the overall structural performance before seismic retrofitting of an existing building. When designing a retrofit project,the engineers should consider how the local retrofitting of structural members would improve the overall performance of structures,and avoid generating new weak components or weak stories with insufficient seismic capacity resulting from the retrofitting. Lessons should be learned from these events for improving the existing seismic assessment methods and retrofitting technologies in the future.
引文
[1]Suzuki K,Hamood A,Maeda M,et al.Performance of the building of the faculty of engineering at Tohoku University during the Great East Japan Earthquake of2011[C].The 10th International Conference on Urban Earthquake Engineering,Tokyo,Japan,2013.
    [2]志賀敏男,柴田明徳,渋谷純一,等.東北大学工学部建設系研究棟における強震応答実測とその弾塑性応答解析[C].日本建築学会論文報告集,2013:119-130.Shiga T,Shibata A,Shibuya J,et al.Observation of strong earthquake motions and nonlinear response analysis of the building of architectural and civil engineering department,Tohoku University[C].Transactions of Architectural Institute of Japan,2013:119-130.(in Japanese)
    [3]日本建築防災協会.既存鉄骨鉄筋コンクリート造建築物の耐震診断基準[S].東京:日本建築防災協会,2001.Japan Building Disaster Prevention Association.Guide line of seismic evaluation and retrofit of existing RC structures[S].2001.(in Japanese)
    [4]Hotta K,Takahashi S,Pujol S,et al.Reduction of ductility of SRC boundary columns by insufficient anchorage of wall bars caused by seismic retrofit[C].The2014 World Congress on Advances in Civil,Environmental,and Materials Research,Busan,Korea,2014.
    [5]Motosaka M.Lessons of the 2011 Great East Japan Earthquake focused on characteristics of ground motions and building damage[C].Proceedings of the International Symposium on Engineering Lessons Learned from the 2011 Great East Japan Earthquake,Tokyo,Japan,2012.
    [6]木村秀樹,平林聖尊,石川裕次,等.東日本大震災による東北大学工学部建物の被害,その3人間環境系研究棟の地震応答解析による検討(1)[C].日本建築学会大会学術講演梗概集,東海,日本,2012.Kimura H,Hirabayashi M,Ishikawa Y,et al.Investigation on building in Tohoku University damaged by the 2011 Great East Japan Earthquake.part 3,study on building of civil engineering and architectural by earthquake response analysis(1)[C].Conference of Architectural Institute of Japan,Tokai,Japan,2012.(in Japanese)
    [7]平林聖尊,木村秀樹,石川裕次,等.東日本大震災による東北大学工学部建物の被害,その4人間環境系研究棟の地震応答解析による検討(2)[C].日本建築学会大会学術講演梗概集,東海,日本,2012.Hirabayashi M,Kimura H,Ishikawa Y,et al.Investigation on building in Tohoku University damaged by the 2011 Great East Japan Earthquake.part 4,study on building of civil engineering and architectural by earthquake response analysis(2)[C].Conference of Architectural Institute of Japan,Tokai,Japan,2012.(in Japanese)
    [8]平林聖尊,木村秀樹,山本正幸,等.RC造骨組架構の履歴特性モデル[C].コンクリート工学年次論文集,名古屋,日本,2005.Ishikawa Y,Kimura H,Yamamoto M,et al.Modeling of hysteresis loops for reinforced concrete frame[C].Proceedings of the Japan Concrete Institute,Nagoya,Japan,2005.(in Japanese)