考虑潮位及动水压力影响的在役海上风电塔地震响应分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
为了准确评价潮间带海上在役风电塔结构在地震作用下的动力特性,以某1 000MW近海及潮间带风电场的风电塔为研究对象,考虑潮位和动水压力影响,对其进行了地震响应分析。基于附加质量法建立了风电塔有限元模型,对平均水深条件和极端高潮位条件下的风电塔结构进行了动力分析,并研究了冲刷效应影响下风电塔结构的自振特性。结果表明:仅考虑潮位变化引起的动水压力对结构的动力响应影响并不大,各项动力性能指标变化均在5%以内;冲刷导致的海床上覆土层的变化将影响到结构的自振周期,进而可能导致风电塔附加振动。
In order to assess the dynamic characteristics of the in-service wind tower structures in intertidal zone under earthquake action,taking a 1 000 MW offshore wind tower in intertidal zone as study object,the earthquake response of the wind tower was analyzed by considering tide level and hydrodynamic pressure.The finite element model of wind tower was established,and the dynamic analyses of structure in mean water depth condition and extreme high tide level condition were carried,and the natural vibration characteristics of wind tower effected by scouring effect were analyzed. The results show that the dynamic response of the structure caused by hydrodynamic pressure is not obvious.The changes of dynamic performance indicators are within5%.The scour will cause the change of soil thickness and lead to the change of dynamic characteristics,which may affect additional vibration of wind towers.
引文
[1]杨万理,李乔.动水压力对连续刚构桥梁地震响应的影响[J].西南交通大学学报,2012,47(3):373-378.YANG Wan-li,LI Qiao.Effects of Hydrodynamic Pressure on Seismic Response of Continuous RigidFramed Bridge[J].Journal of Southwest Jiaotong University,2012,47(3):373-378.
    [2]张国明,宋波.动水压力对深水桥梁性能设计的影响[J].北京科技大学学报,2009,31(9):1086-1094.ZHANG Guo-ming,SONG Bo.Effect of Hydrodynamic Pressure on Performance-based Design of a Deepwater Bridge[J].Journal of University of Science and Technology Beijing,2009,31(9):1086-1094.
    [3]杨庸.动水压力对深水高墩大跨度连续刚构动力特性的影响[J].四川建筑,2014,32(2):168-171.YANG Yong.Influence of Hydrodynamic Pressure on Dynamic Characteristics of Deepwater High-pier and Long-span Continuous Rigid Frame[J].Sichuan Architecture,2014,32(2):168-171.
    [4]CHOPRA A K,GOYAL A.Simplified Earthquake Analysis of Intake-outlet Towers[J].Journal of Structural Engineering,1991,117(3):767-788.
    [5]LIAW C Y,CHOPRA A K.Dynamic of Towers Surrounded by Water[J].Earthquake Engineering&Structural Dynamics,1974,3(1):33-49.
    [6]白志刚,裴丽,阳磊.潮间带风电场水动力数值模拟[J].港工技术,2012,49(3):1-4.BAI Zhi-gang,PEI Li,YANG Lei.Hydrodynamic Numerical Simulation for Wind Farm in Intertidal Zone[J].Port Engineering Technology,2012,49(3):1-4.
    [7]李富荣,陈国兴,王志华.考虑动水压力影响的单柱式桥墩地震反应分析[J].地震工程与工程振动,2008,28(2):114-121.LI Fu-rong,CHEN Guo-xing,WANG Zhi-hua.Seismic Responses of Single-column Pier Considering the Effects of Hydrodynamic Pressure[J].Journal of Earthquake Engineering and Engineering Vibration,2008,28(2):114-121.
    [8]田树刚,陈清军.考虑流固耦合的近海风电支撑体系自振特性分析[J].力学季刊,2014,35(3):473-481.TIAN Shu-gang,CHEN Qing-jun.Analysis of Dynamic Characteristics of Offshore Wind Power Foundation with Consideration of Fluid-structure Interaction[J].Chinese Quarterly of Mechanics,2014,35(3):473-481.
    [9]张陆陈,骆少泽.近海风力发电机基础桩群潮汐水动力脉动特性试验研究[J].工程力学,2010,27(增1):236-239.ZHANG Lu-chen,LUO Shao-ze.Study on Tidal Flow Fluctuating Pressure Properties of Offshore Wind Generators Pile Group Foundation[J].Engineering Mechanics,2010,27(S1):236-239.
    [10]荣冰,张嘎,张建民.水平荷载作用下风电机桩基础的离心模型试验研究[J].岩土力学,2012,33(2):428-432.RONG Bing,ZHANG Ga,ZHANG Jian-min.Centrifuge Model Tests for Pile Foundation of Wind Power Generation Under Horizontal Loads[J].Rock and Soil Mechanics,2012,33(2):428-432.
    [11]李凯文,宋波,黄帅.考虑流固耦合效应的海上单桩式风电塔动力响应研究[J].建筑结构学报,2014,35(4):318-324.LI Kai-wen,SONG Bo,HUANG Shuai.Dynamic Response Analysis of Offshore Wind Tower Founded on Monopile Considering FSI[J].Journal of Building Structures,2014,35(4):318-324.
    [12]棚邉隆,飯田泰彦,増田博,等.風力発電設備の動的特性と耐震設計の基礎的考察[J].NKK技報,2002(177):64-69.TANABE Takashi,IIDA Yasuhiko,MASUDA Hiroshi,et al.A Fundamental Study on Dynamic Characteristics and the Seismic Design of Wind Turbine Generator Systems[J].NKK Technical Report,2002(177):64-69.
    [13]佐野健彦,石原孟.非線形FEM解析に基づく風車無筋ペデスタルの耐力評価式の提案[J].構造工学論文集,2014,60:134-143.SANO Takehiko,ISHIHARA Takeshi.Design Formulae on Concrete Capacity of Wind Turbines Pedestal Based on the Non-linear FEM Analysis[J].Journal of Structural Engineering,2014,60:134-143.
    [14]KIM D H,LEE S G,LEE I K.Seismic Fragility Analysis of 5 MW Offshore Wind Turbine[J].Renewable Energy,2014,65:250-256.
    [15]戴靠山,公常清,黄益超,等.适用于风电塔抗震设计的低阻尼反应谱[J].地震工程与工程振动,2013,33(6):40-46.DAI Kao-shan,GONG Chang-qing,HUANG Yichao,et al.Response Spectra for Seismic Design of Low Damping Wind Turbine Towers[J].Journal of Earthquake Engineering and Engineering Vibration,2013,33(6):40-46.
    [16]戴靠山,王健泽,毛日丰,等.新型风电塔减振器的概念设计和试验初步验证[J].土木工程学报,2014,47(增1):90-95.DAI Kao-shan,WANG Jian-ze,MAO Ri-feng,et al.Conceptual Design and Shaking Table Test of a New Passive Damper for Wind Turbine Towers[J].China Civil Engineering Journal,2014,47(S1):90-95.
    [17]高春彦,李斌,史治宇.钢管混凝土风电塔架节点非线性有限元分析[J].建筑结构学报,2013,34(增1):140-146.GAO Chun-yan,LI Bin,SHI Zhi-yu.Nonlinear Finite Element Analysis of Concrete-filled Steel Tubular Wind Turbine Tower Joints[J].Journal of Building Structures,2013,34(S1):140-146.
    [18]陈阳,宋波,韦伟,等.在役风电塔结构的最不利风-震组合作用响应分析[J].北京科技大学学报,2013,35(7):941-947.CHEN Yang,SONG Bo,WEI Wei,et al.Dynamic Response Analysis on the Structure of Wind Power Towers Under the Most Unfavorable Wind-earthquake Combination Action[J].Journal of University of Science and Technology Beijing,2013,35(7):941-947.
    [19]张鹏林,曹力,刘九逍,等.风电塔筒在三种工况下的静动态研究[J].机械设计与制造,2013(10):200-202.ZHANG Peng-lin,CAO Li,LIU Jiu-xiao,et al.Research on Wind Turbine in the Three Conditions of Static and Dynamic[J].Machinery Design&Manufacture,2013(10):200-202.
    [20]宋波,曾洁.风电塔非线性地震动力响应规律与极限值评价[J].北京科技大学学报,2013,35(10):1382-1389.SONG Bo,ZENG Jie.Nonlinear Seismic Dynamic Response and Critical Value Evaluation Based on Limit States of Wind Turbine Tower Structures[J].Journal of University of Science and Technology Beijing,2013,35(10):1382-1389.
    [21]公常清,戴靠山,任晓崧.随机地震动摇摆分量对风电塔结构地震响应影响的分析[J].土木工程学报,2013,46(增1):275-280.GONG Chang-qing,DAI Kao-shan,REN Xiao-song.Seismic Analysis of Wind Turbine Towers Under Rocking Earthquake Components[J].China Civil Engineering Journal,2013,46(S1):276-280.
    [22]ALHAMAYDEH M,HUSSAIN S.Optimized Frequency-based Foundation Design for Wind Turbine Towers Utilizing Soil-structure Interaction[J].Journal of the Franklin Institute,2011,348(7):1470-1487.
    [23]张德文,张建民.桩基础抗震性能的简易评价方法[J].地震工程学报,2013,35(1):69-83.ZHANG De-wen,ZHANG Jian-min.Simplified Method for Evaluating Seismic Performance of Pile Foundation[J].China Earthquake Engineering Journal,2013,35(1):69-83.
    [24]赖伟,郑铁华,雷勇.Morison方程中动水阻力项对桥梁桩柱地震反应的影响[J].四川建筑科学研究,2007,33(4):163-168.LAI Wei,ZHENG Tie-hua,LEI Yong.The Effect of Hydrodynamic Drag Force in Morison Equation on the Seismic Response of Piles[J].Sichuan Building Science,2007,33(4):163-168.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心