福州地震台TJ-2型体积式应变仪安装及注水试验
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
在安装福州地震台TJ-2型体积式应变仪过程中,发现存在钻孔选点与观测室分开考虑等问题,提出一些建议。井孔注水试验结果揭示,该井孔探头顶部可能存在一个与探头近距离的含水层干扰。初步对气压、水位、降雨影响进行分析。
Problems appeared in the installing Tj-2tpye volume strain meter in Fuzhou seismic station,that where drill the hole and where to be the observing room were considered at different time and so on,are discussed and some suggestions are given.The results of the drill-hole water injection test in Fuzhou seismic station indicated that the thickness of the cement layer on the top of sensor did not reach design request and there is the disturbance of aquifer layer in the segment of the drill-hole to the strain-meter observation.The influence of atmospheric pressure and water level and rainfall to the volume strain is analyzed.
引文
[1]苏恺之,李海亮,张均,等.钻孔地应变观测新进展[M].北京:地震出版社,2003.1-62.
    [2]中国地震局监测预报司.地壳形变数字观测技术[M].北京:地震出版社,2003.50-102.
    [3]中国地震局监测预报司.地震数字化观测规范[M].北京:地震出版社,2002.1-30.
    [4]王大纯,张人权.水文地质学基础[M].北京:地质出版社1980.78-96.
    [5]陈德福,李玉.怀来等台固体潮观测调和分析结果[J].华北地震科学,2000,18(2):41-46.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心