408UL仪器地面设备防雷器
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
近年来,在实际生产中多次发生雷击造成仪器地面设备(主要是408UL仪器采集站FDU)损毁的事故。本文根据对现场的调查,分析了地震仪器防雷击的技术措施,介绍了“408UL仪器地面设备防雷器”(以下简称防雷器)及其室内测试和野外试验情况,提出并分析了应用于地震仪器系统防雷击的一些技术措施和设想。
In recent years,the accidents that struck of lightning does damage to surface instruments in 408UL seismograph(mainly acquisition station FDU) have appealed many times in practical production.The paper,according to on-the-spots investigation,analyzed the technical measures of protecting seismograph from struck of lightning,introduced "lightning conductor of surface instruments in 408UL seismograph"(simply called lightning conductor in follows) and the situation of indoor tests and field experiments,and presented and analyzed some technical measures protecting seismograph systems against lightning applied.
引文
1 Sercel公司.408UL仪器用户手册.2005
    2夏祥瑞.避雷与避雷措施.物探装备,2000,14(1)
    3张留争.浅谈408XL仪器采集系统的雷电防护.物探装备,2005,15(2)

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心