数字化体应变仪观测值突跳的分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
山东长清台数字化体应变仪观测曲线自 1 999年以来出现几次形态类似的大幅度突跳 ,为正确认识这类现象 ,在长清台做了交直流切换对观测值影响试验 ,并对水位、气压资料进行综合分析。研究结果表明 ,水位、气压、电源切换等因素不会引起体应变仪观测曲线的突跳。对比其他类似观测分析推测 ,这类突跳可能与“慢地震”事件或“岩孔崩落”现象有关
The observed data of the body-strain meter at Changqing Station in Shandong Province, occurred several times of similar sudden jump with large amplitude. In order to recognize the phenomena, we conducted a test about the switchover of the alternating current and direct current, and analyzed synthetically the data of the water level, and atmospheric pressure. The results show that all the water level, the atmospheric pressure and the switch of the power supply cannot cause the sudden jump of the observed data. Compared with other similar observations, we consider that such jump may be related with the "slow earthquake" events or the "bore-hole collapsing".
引文
[1] 国家地震局科技监测司.地震地形变观测技术[M].北京:地震出版社,1995.229-233,347-349
    [2] 国家地震局科技监测司.中国地震预报方法研究[M].北京:地震出版社,1991.423-443.
    [3] SelwynSacks.应力重新分布和缓慢地震[J].世界地震译丛,1983,(1):16-19.
    [4] 张绍治,范桂英.近区有震异常与无震异常的判别[J].地震,1987,7(1):23-26

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心