清水池震害评估模型研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
为了评估清水池的地震破坏状态,基于海城地震、唐山地震中较详细的水池震害资料,分析了水池的主要震害现象、特征,并找出了影响水池震害的主要因素。采用最小二乘法对震害数据进行回归分析,得到了各震害影响因素不同情况下的回归系数取值,从而建立了清水池震害经验统计回归模型。经计算该模型的相关系数为0.661,标准差为0.447。经回判分析,模型回判成功率为91.2%。对于模型中未考虑到的震害影响因素,根据实际震害经验,给出新增影响因素的建议系数。对汶川、玉树等地震中遭到破坏的清水池进行评估,结果与实际震害基本相符,初步验证了该评估模型的可靠性。
In order to assess the seismic damage of clean water tanks,based on the detailed earthquake damage data of clean water tanks from Haicheng earthquake and Tangshan earthquake,the phenomena and characteristics of clean water tanks subjected to earthquake damage are analyzed and the main influence factors are found.The least square method is used in the regression analysis of the earthquake damage data to obtained the regression coefficients of influence factors of earthquake damage under different conditions and to establish an empirical model to evaluate the earthquake damage of clean water tanks.The correlation coefficient of the model is 0.661 and the standard deviation is 0.447.The model has an accuracy of 91.2% by the regression discriminant analysis.According to the earthquake experience,the adjustment coefficients for new influence factors that are not considered in the model are given.Evaluation results are consistent with the actual damage to the clean water tanks in Wenchuan earthquake and Yushu earthquake,and etc.Thus,the model is preliminarily proved to be reliable.
引文
[1]中国科学院工程力学研究所.海城地震震害[M].北京:地震出版社,1979.
    [2]中国地震局工程力学研究所.汶川地震工程震害科学考察总结报告[R].哈尔滨:中国地震局工程力学研究所,2009.
    [3]郭恩栋,冯启民,高惠瑛,等.矩形钢筋混凝土水处理池震害预测方法及抗震对策[J].地震工程与工程振动,1998,18(2):33-37.
    [4]裴宗广,刘尧兴,王晓青,等.供水水池的震害预测[J].华北地震科学,2005,23(2):28-31.
    [5]付敏,聂树明,杜鹏.东莞市区矩形钢筋混凝土水池震害预测[J].华南地震,2008,28(3):44-48.
    [6]崔玉红,邱虎,聂永安,等.国内外单体建筑物震害预测方法研究述评[J].地震研究,2001,24(2):175-182.
    [7]HOSKIN L M,JAEOBSEN L S.Water pressure in a tank caused by a simulated earthquake[J].Bulletin of the Seismolog-ical Society of America,1934,24(1):1-32.
    [8]HOUSNER G W.Dynamic pressure on aecelerated fluid container[J].Bulletin of the Seismological Society of America,1957,47(1):15-35.
    [9]HOUSNER G W.Behavior of structures during earthquake proceedings[J].Journal of Engineering Mechanics Division,1959,85:35-42.
    [10]ANDRIANARISON O,OHAYON R.Compressibility and gravity effects in internal fluid-structure vibrations:Basic equa-tions and appropriate variational formulations[J].Com Put Methods APPI Mech Engrg,2006,195:1958-1972.
    [11]刘云贺,王克成,陈厚群.储液池的抗震问题探讨[J].地震工程与工程振动,2005,25(1):149-154.
    [12]刘洁平,胡明祎,张令心.考虑液固耦合水池地震反应分析方法及其应用[J].哈尔滨工业大学学报,2011,43(S1):182-187.
    [13]张飘.给水排水工程结构[M].北京:机械工业出版社,2010.
    [14]高霖,郭恩栋,王祥建,等.供水系统水池震害分析[J].自然灾害学报,2012,21(5):120-126.
    [15]全国地震标准化技术委员会(SAC/TC225).GB/T24336-2009生命线工程地震破坏等级划分[S].北京:中国标准出版社,2009.
    [16]郭恩栋,张丽娜,王亚东,等.土坝震害评估模型研究[J].岩土力学,2011,32(12):3667-3671.
    [17]王家全,张信贵,易念平,等.场地土卓越周期变化的试验分析[J].广西大学学报:自然科学版,2010,35(4):684-692.
    [18]袁一凡.岩土工程结构震害预测方法研究[R].哈尔滨:中国地震局工程力学研究所,2000:3-22.
    [19]北京市市政工程设计研究总院.GB50332-2002给水排水工程管道结构设计规范[S].北京:中国建筑工业出版社,2002.
    [20]新疆维吾尔自治区地震局.新疆于田—策勒7.3级地震灾害损失及地震烈度分布[EB/OL].2009-02-09[2012-10-28].http://www.eq-xj.gov.cn/manage/html/ff808181126bebda01126bec4dd00001/_content/09_02/09/1234166909353.html.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心