新疆测震台站部分常发故障分析与讨论
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对新疆测震台站各类仪器设备经常出现的部分故障进行总结,内容涵盖地震数据采集系统、台站电源系统、台站数据通信系统经常出现的各类故障,阐述了故障表象,对故障产生原因进行分析与总结,并提出相应解决方案。对多种类型地震专业设备、多类台站通信方式进行对比分析,阐述了在实际使用中各自的优缺点与适用性,以期在台站改造与建设中起到参考作用。
The authors summarized some frequent troubles of all instruments and equipment in Xinjiang seismic stations,such as data acquisition system,power supply and communication system,stated superficial phenomenon,analyzed the cause of the trouble and presented the corresponding solution. After analyzing all kinds of seismologic profession equipment,communication mode in some stations comparatively,the authors expressed the merit and demerit,applicability of them,which will be helpful for the station transformation and construction in future.
引文
[1]王登伟,张艺,戴仕贵,等.用微型地下室坑式摆墩方式解决BBVS-60宽频带地震计零漂问题[J].四川地震,2009,1:20-24.
    [2]林森,武拥军.MSS对GPS的干扰分析[J].无线电通信技术,2004,30(6):53-57.
    [3]张海林,徐甲强,王平,等.环境温度对阀控密封铅酸蓄电池的影响及应对措施[J].电力系统通信,2007,28(178):44-46.
    [4]王宝柱,李晓东,袁顺.新疆地震台网超短波传输系统及故障分析[J].内陆地震,2008,22(4):339-347.
    [5]陈述新,史勇军,罗刚.VPN技术在新疆地震行业网中的应用[J].内陆地震,2009,23(2):291-296.