厦门地震台3066型记录仪故障现象及分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
厦门台垂直摆模拟记录曲线接连出现几次畸变现象,通过对比分析数字化记录和模拟记录曲线,查找干扰原因,认为很可能是静电对模拟记录仪的干扰影响。
It is the responsibility of observers to assure that instrument runs normally and continuously.Aberration appeared in analog record curves of the vertical pendulum of Xiamen Seismostation in succession recently.In this paper,the cause of interference is investigated by comparing digitized records and analog recorder curves,and it is believed the interference probably arises from the effect of static electricity upon the analog recorder.But there also are probably other interference factors,which need further observation and study.
引文
[1]张远城,熊先保,黄晓华.数字化形变台站观测资料质量跟踪分析[J].大地测量与地球动力学,2003,23(4):125-128.
    [2]杨婕.厦门地震台数字化仪器零点台阶产生原因探讨[J].地震地磁观测与研究,2009,30(1):98-102
    [3]中国地震局监测预报司.地壳形变数字观测技术[M].北京:地震出版社,2003,36-36
    [4]唐洪舰.浅谈石油库静电的危害与预防[J].中国油脂,2008,33(6):72-73
    [5]洪玉.不可轻视的静电[J].知识就是力量,2005,(1):26-26
    [6]郑柯献,周玲,陈维超,等.琼中地震台防雷措施研究与实践[J].地震地磁观测与研究,2005,26(5):100-105.
    [7]叶春明,吕金水.数字地震台网观测系统工作环境的改造[J].华南地震,2000,20(4):27-31
    [8]曹琳瑞.谈无尘纸成型过程的静电影响与消除[J].江苏造纸,2001,(1):40-40