震后某工号建渣及土壤样品中铀的分析测定
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
采用激光荧光法对"5.12"地震后某工号建筑垃圾和土壤样品进行了铀的测定。方法检出下限D.L≤3×10-11g/mL,相对标准偏差RSD为7.4%,回收率达到86%~109%。对实验数据进行了分析和初步评价,结果表明,该工号所测样品铀含量基本处于天然本底水平。
Uranium in building trash and soil samples from "May 12" earthquake area were determined using laser fluorescence spectrophotometry.The detection limit,relative standard deviation(RSD) and recovery rate were ≤3×10-11g/mL,7.4% and 86%~109% respectively.The experimental data were analyzed and evaluated initially.The results showed that the uranium content of this location was at the normal level of background.
引文
[1]杨乡珍.铀的光度分析进展[J].湿法冶金,2002,21(3):154-159.
    [2]文世荪.铀试剂Ⅲ分光光度法测定铀[J].上海预防医学杂志,1997,9(6):272-273.
    [3]GB6768-86,水中微量铀分析方法[S].
    [4]EJ/T823-94,激光荧光微量铀分析仪[S].
    [5]EJ/T550-2000,土壤、岩石等样品中铀的测定-激光荧光法[S].
    [6]张彩虹.激光荧光法直接测定环境样品中的微量铀[J].核技术,1999,22(9):551-556.
    [7]郭一飞,梁俊福,焦荣洲,等.激光荧光法测定高放废液处理工艺中的铀[J].原子能科学技术,1997,31(4):321-327.
    [8]文世荪.环境中铀及其测定[J].安徽预防医学杂志,2000,6(6):471-473.