站桥合一地铁高架车站抗震性能分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
以北京某地铁高架车站为背景,建立了有斜撑与无斜撑站桥合一高架车站的有限元计算模型,分析了高架车站上、下层墩柱在地震作用下的位移响应。结果表明,地震作用下,有斜撑站桥合一高架车站与无斜撑站桥合一高架车站相比,墩柱顶部的竖向位移相差较小,斜撑对站桥合一高架车站竖向抗震作用并不明显;与无斜撑站桥合一高架车站相比,有斜撑站桥合一高架车站上层墩柱的横纵向水平位移响应有大幅降低,车站结构在水平方向上的抗震性能提高较大;有斜撑站桥合一高架车站的结构整体性更好,抗震性能更强,结构形式更合理。
The results show that under the action of earthquake, comparing an elevated station with diagonal brace and an elevated station without diagonal brace, the differences between vertical displacements of top of piers of the elevated stations with diagonal brace are small and the brace for elevated station for vertical seismic effect is not obviousompared with the elevated station without diagonal brace, transverse and longitudinal horizontal displacement response on its upper pier for the elevated station with a diagonal brace is greatly reduced, the seismic resistance performances of the station structure in horizontal direction are greatly improved.
引文
[1]赵毓成,李文会.城市轨道交通高架车站结构形式分类及适用研究[J].铁道标准设计,2013(1).
    [2]唐坚.轨道交通高架站桥建关系的类型化分析[J].暨南大学学报,2011,12(1).
    [3]赵杰林.独柱式长悬臂高架车站地震安全性探讨[J].建筑结构,2012(4).
    [4]赵涛.桥建合一高架车站结构抗震分析方法探讨[J].中国水运,2013,13(5).
    [5]李钊.“站桥合一”式车站结构简化抗震性能研究[D].北京:北京交通大学,2011.
    [6]李献忠,张媛,丁阳.轻轨铁路站桥结构体系抗震分析与隔震研究[J].地震工程与工程震动,2003,23(6).
    [7]G B50011-2010建筑抗震设计规范[S].2010.
    [8]G B50111-2006铁路抗震设计规范[S].2009.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心