基于小波变换的小电流接地系统的行波测距
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
阐述了基于小波变换的行波测距法 ,针对小电流接地系统中存在的架空线电缆交替出现的现象 ,首次提出了消除波速度不连续的归一算法 ,以实现该系统中行波测距法。通过理论分析和仿真论证了该算法为小电流接地系统单相接地的故障测距 ,并提出了新的方法
This paper discusses the algorithm of fault distance measurement with traveling wave based on Wavelet transform. For the instance of the alternation of overhead lines and cables in the non direct grounded neutral system this paper brings forward the algorithm of velocity conversion to singleness to eliminate the discontinuity of traveling wave velocity and to implement this algorithm. Both the theory analysis and results of simulation prove that the algorithm is feasible, consequently provides a new algorithm for the single grounded fault distance measurement in the non direct grounded neutral system.
引文
1 徐丙垠,李 京,陈 平等现代行波测距技术及其应用[J].电力系统自动化,2001,23(12):6265
    2 郑治真,沈 萍,杨选辉等小波变换及其MATLAB工具的应用[M].北京:地震出版社,2001
    3 董新洲,贺家李,葛耀中小波变换第3讲 二进小波变换及信号的奇异性检测[J].继电器,1999,27(3):6568
    4 邱毓昌,施 围,张文元高电压工程[M].西安:西安交通大学出版社,2001
    5 华北电力学院电力系统故 障分析[M].北京:水利电力出版社,1979
    6 龚庆武,来文青,吴 夙用MATLAB和EMTP对输电线路进行故障定位数字仿真的比较[J].华北电力技术,2001,(10):3134

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心