多级变刚度滞变耗能的设计思想和可行性实验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
本文提出一种多级变刚度滞变耗能器,讨论了其设计的基本思想,并进行了初步的试验研究。结果表明,不管是增刚度型还是减刚度型多级变刚度耗能器均具有很好的滞变耗能能力,可以应用于被动自适应 (或称为智能)控制。
In this paper, the multistage-stiffness-variable and hysteretic energy dissipation apparatus is discussed, and its design method is presented. The conclusion is that both the stiffness-added ap paratus and the stiffness-reduced one have good hysteretic energy dissipation behavior. So they can be used in the self-adapted passive control system (Intelligent control system).
引文
[1]周云,刘季.加劲阻尼装置在建筑抗震中的应用[J].工程抗震,1997(1):34-38
    [2] 周云.建筑耗能减震新技术与新体系[C].哈尔滨建筑大学博士学位论文.1996.
    [3] 吴斌.滞变型耗能减震体系的试验、分析和设计方法[C].哈尔滨建筑大学博士学位论文,1998
    [4] Laura Anania. Experimental Analysis and Analytical Modelling of an Innovative Elasitic-plastic Dissipation Device for Seis-mic Protection of the Structures[A]. Proceedings of 12th WCEE[C]. Auckland, 2396, 2000.
    [5] Xavier Cahis. Lluis Torres, Luis Bozzo. An Innovative Elasto- plastic Energy Dissipator for the Structural andNon-structural Building Protection[A]. Proceedings of 12th WCEE[C].Auckland, 0382. 2000.
    [6] 郭迅,张敏政.新型钢滞变阻尼器的研究[A].第四届全国地震工程会义论文集[C].1994:5-96-5-99
    [7] 赵桂峰.变刚度被动控制体系的研究[D].哈尔滨工业大学工学博士学位论文,2001

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心