预压装配式预应力混凝土框架是采用工厂化生产的预制柱和预制预应力梁,运至现场直接吊装,梁柱就位后,将后张预应力筋穿过梁柱预留孔道,对节点实施预应力张拉预压。后张预应力筋既可作为施工阶段拼装手段,又可在使用阶段承受梁端弯矩,构成整体受力节点和连续受力框架,克服了装配式节点受力可靠性差的缺陷,解决了预应力混凝土框架难以装配的问题,形成预制预应力混凝土装配整体式框架,开辟了预应力结构工业化生产的新途径。
     本文通过两榀预压装配式梁柱组合体在低周反复荷载下的试验,了解了预压装配式框架梁端截面应变分布、破坏机理和极限承载能力;探讨了全预应力配筋截面延性特征、滞回性能、耗能能力和变形恢复能力。
Subassemblage and Prestressed concrete frames are assembled by precast prestressed beams and columns with tendons in the joints of the frames.These beams and columns are hoisted in site and the tendons are passed through the moire pipes.So prestressing force are brought to the joints of the frame.These tendons also can assume the moments at the end of the beams in ordinary condition. By way of these tendons,precest beams and columns can be assembled conveniently,and the joints and frame are monolithic and continuous.Consequently,compared with common reinforced concrete frams,this kind of frame systems possess higher reliability and solved the problems in the process of assembling Prestressed Concrete frames.Also it forms the framework of Subassemblage and Prestressed Concrete Frames,and explores a new way for industrial production of prestressed structures.
    Tow speciments of prestressed fabricated beam-column subassembly were tested under reversed cyclic loading. Experimental studies were carried out to investigate the strain distribution, failure mechanism and load-bearing capacity on the beam-column connections, as well as ductility, hysteresis curves energy dissipation, displacement restoring capacity of full PC speciments.
引文
[1]L.莫克,E.栾凯著.傅信祁,徐鼎新等译.钢筋混凝土装配式建筑[M].中国建筑工业出版社,1985年2月
    [2]北京建筑工程学院建筑技术教研组.装配式建筑设计[M].中国建筑工业出版社.1983年6月
    [3]《装配式大板建筑》组.装配式大板建筑[M].中国建筑工业出版社,1977年12月
    [4]久田俊彦著,姜敦超译.地震与建筑[M].地震出版社,1978年8月
    [5]中国建筑工业出版社编.唐山地震抗震调查总结资料选编[M].中国建筑工业出版社.1977年2月
    [6]苏小卒.预应力混凝土框架抗震性能研究[M].上海科学技术出版社,1998年10月
    [7]华东预应力混凝土技术开发中心.现代预应力混凝土工程实践与研究[M].光明日报出版社.1989年5月
    [8]唐九如.钢筋混凝土框架节点抗震[M].东南大学出版社.1989年
    [9]Negoita A et al. The seismic analysis, theoretical and experimental, of the joints of prestressed concrete frames. CEB Bulletin D'inf ormation, 1979, No. 132bis:53~61
    [10]Magdy T. EL-Sheikh, Richard Sause. Seismic Behavior and Design of U nbonded Post-Tensioned Precast Concrete Frames[J],PCI Journal, May-June, 1999, p54-71.
    [11]Geraldine S. Cheok, H.S. Lew, Ph.D. Model Precast Concrete Beam-to-Co lumn Connections Subject to Cyclic Loading[J]. PCI Journal. July-August 1993, p80-92.
    [12]M.J. Nigel Priestly, Ph.D.,Gregory A.MacRae, Ph.D. Seismic Tests of Precast Beam-to-Column joint Subassemblages With Unbonded Tendons[J]. PCI Journal. August 1996, p44-53.
    [13]Blakeley R W G, Park R. Seismic resistance of prestressed concrete beam-column assemblies. J. ACI, Sept 1971:677~692
    [14]Alvarez Baleriola Jose Iet al. Ductile behavior of joints in pre cast members assembled by means of pretressing under seismic loa ding. CEB Bulletin D'information, No. 132
    [15]张瑜中,藤本一郎,PCaPC压着工法二次应力歪研究.[A].日本建築学会.日
    
    ??本建篥学会大会学衍耩演梗概集[C].日本,北海道,1995年
    [16]後藤寿之,保坂时雄.柬京货物矩梭合施设耩造设计PC建筑特集设计报告[A].日本,1992.
    [17]周旺华.现代混凝土叠合结构[M].中国建筑工业出版社,1998年9月:
    [18]陈勇.无粘结预应力砼框架节点抗震性能研究[D].福州大学硕士学位论文.2002年1月
    [19]薛伟辰.现代预应力结构设计(按新规范编写)[M].中国建筑工业出版社.2003年3月
    [20]湖南大学,太原工学院,福州大学合编.建筑结构试验[M].中国建筑工业出版社.1982年7月
    [21]沈在康.混凝土结构试验方法新标准应用评讲[M].中国建筑工业出版社.1994年1月
    [22]姚振纲,刘祖华.建筑结构试验[M].同济大学出版社.1996年9月
    [23]JGJ101-96,建筑抗震试验方法规程[S].
    [24]林飞.无粘结部分预应力混凝土框架抗震性能研究[D].福州大学硕士学位论文.2000年12月
    [25]熊学玉,朱莉莉,赵勇.现代预应力混凝土结构正截面极限强度分析[J].结构工程师.2000年1月
    [26]叶列平.混凝土结构(上、下册)[M].清华大学出版社,2002年1月:
    [27]蓝宗建,梁书亭,孟少平.混凝土结构设计原理[M].东南大学出版社.2002年4月
    [28]GB500 10-2002,混凝土结构设计规范[S]
    [29]房贞政.无粘结与部分预应力结构[M].人民交通出版社,1999年10月:
    [30]T.鲍雷,M.J.N.普里斯特利著.戴瑞同,陈世鸣等译.钢筋混凝土和砌体结构的抗震设计[M].中国建筑工业出版社.1999
    [31]朱唯贤.钢筋混凝土偏心节点扭转效应试验研究及理论分析[D].合肥工业大学硕士学位论文.2002年5月
    [32]邵晓健.不同强度混凝土梁柱节点的抗震性能[D].同济大学硕士学位论文.2002年1月
    [33]吴善能,朱伯龙.钢筋混凝土框架梁-柱-节点系统破坏界限的研究.结构工程师[J].1998年3月
    [34]武汉水利电力学院建筑力学教研室编.材料力学(第二版)[M].高等教育出版社.1983年6月
    [35]柳炳康,黄慎江,周安等.钢筋混凝土框架偏心节点抗震性能的试验研究[J].建筑结构学报.1999年5月
    [36]傅剑平,游渊,白绍良.钢筋混凝土抗震框架节点的受力特征分析[J].重庆
    
    ??建筑大学学报.1996年6月
    [37]日本建筑构造技术者协会.建筑结构[M].北京:中国建筑工业出版社,2000.104-105.
    [38]施养杭.现浇钢筋砼框架梁柱节点力学性能分析[J].华侨大学学报(自然科学版).1994年10月
    [39]傅剑平,游渊,白绍良.钢筋混凝土抗震框架节点传力机构分析[J].重庆建筑大学学报.1996年3月
    [40]杜拱辰.现代预应力混凝土结构[M].中国建筑工业出版社.1988年9月
    [41]李昆.预应力组合梁框架结构抗震性能研究[D].同济大学硕士学位论文.2002年2月
    [42]王静峰,柳炳康,孙捷.钢筋混凝土框架偏心节点的抗裂性能[J].同济大学学报(自然科学版).2003年12月

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700