A statistics-based FO membrane characterization method was developed. The statistical approach finds FO membrane parameters using ICP and ECP models. Consideration of ECP helps to determine more accurate FO membrane parameters. The parameters from the FO method predict the FO membrane behavior fairly well. Pressurized RO experiment may not need to obtain FO membrane characteristics.