广晟国际大厦罕遇地震弹塑性时程分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
采用基于显式积分的弹塑性动力分析方法,对一栋高度约312m超B级高度的超限高层建筑进行了罕遇地震弹塑性时程分析,以了解结构在罕遇地震下的弹塑性行为。结果表明,基于显式积分动力分析法的弹塑性时程分析是保证结构大震不倒的有效方法,本工程采用的框架核心筒结构形式具有较高的抗震承载力和延性,能够满足"大震不倒"的建筑抗震设防目标。
In this paper, the elasto-plastic time-history analysis of a 312m, super-B rating high building under a rare earthquake was carried out by the elasto-plastic dynamic analysis method base on explicit integration, in order to understand the elasto-plastic behaviour of this structure when suffering a rare earthquake. The result showed that the elasto-plastic dynamic analysis method base on explicit integration is an effective approach which could make sure the structure stay up under a rare earthquake, and the frame-coretube structure form applied to this project had a good seismic bearing capacity and ductility which could achieve the third level seismic fortification object of criterion.
引文
[1]JGJ3—2002高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2002.
    [2]GB50011—2001建筑抗震设计规范[S].北京:中国建筑工业出版社,2001.
    [3]广州瀚华建筑设计有限公司,广州数力工程顾问有限公司.广晟国际大厦罕遇地震弹塑性时程分析报告[R],2007.
    [4]广州瀚华建筑设计有限公司.广晟国际大厦超限设计可行性报告[R],2007.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心