短肢剪力墙墙肢轴压比限值研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
基于界限破坏时的内力平衡条件,详细推导了L形钢混凝土短肢剪力墙轴压比限值的理论计算公式,对工程中较优截面,按照规范规定配筋率等进行计算,对现行规范中关于短肢剪力墙的轴压比限值提出了建议,并以此类推,对其T形截面,一字形截面给出轴压比限值建议值。
Based on the limits of the internal forces destroyed the equilibrium condition,it is derived theoretic formula of axial compression ratio of L-shaped steel-concrete short-limb shear wall.The optimum cross-section of the project is calculated according to the specified reinforcement ratio etc in codes;it is also recommended the axial compression ratio limib in the current code for short-limb shear wall,T-shaped and I-shaped short-limb shear walls.
引文
[1]JGJ 3—2002高层建筑混凝土结构技术规程[S].
    [2]GB 50010—2002混凝土结构设计规范[S].
    [3]刘阳,郭子雄,张志伟。核心型钢混凝土柱的轴压比限值试验研究[J].2008,28(3):82-86.
    [4]曹万林,王丽.钢筋混凝土带暗支撑Z形截面短肢剪力墙抗震性能试验研究[J].世界地震工程,2004,20(3):84-89.
    [5]黄承逵,王丹,崔博.钢筋混凝土异形柱轴压比限值研究[J].大连理工大学学报,2002(2):213-217.
    [6]陈道政,李爱群.钢筋混凝土柱轴压比限值控制的讨论[J].工业建筑,2002,32(8):75-76.
    [7]华新钰.短肢剪力墙轴压比限值的研究[D].南京:南京航空航天大学,2008:17-24.
    [8]程文瀼,李爱群,张晓峰,等.钢筋混凝土柱的轴压比限值[J].建筑结构学报,1994(6):25-30.
    [9]苏益声,温远辉.不对称截面钢筋混凝土短肢墙试验研究[J].建筑结构,2002,32(8):7-9.
    [10]李启华,刘世美.短肢剪力墙中相关参数对其弹塑性性能的影响[J].武汉理工大学学报,2008,30(8):122-125.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心