摘要
为辐射环境监测设计一个低本底实验室,从位置、建材、宇宙射线、屏蔽、防氡、电气和施工各方面综合考虑,最终得到空气吸收剂量率27.2nGy/h,氡浓度降为10Bq/m~3的满意结果。
This paper was to design a low-background laboratories for radiation environment monitoring. Considering location, building materials, cosmic rays,shielding, radon mitigation, electrical and construction factors,The end result:air absorbed dose rate was 27.2 nGy/h and radon concentration was 10 Bq/m~3.
引文
[1]马如维,张艾明.浙江省环境保护实验综合楼低本底实验室的概念设计[M].内部资料,2002.
[2]刘广山等.地下铁室铅室组合屏蔽低本底HPGeγ谱仪测量系统及其应用[J].辐射防护,1997,17(6).
[3]编写组.环境放射性监测方法[M].北京:原子能出版社,1977.
[4]复旦大学,清华大学,北京大学.原子核物理实验方法[M].北京:原子能出版社,1996.
[5]潘自强,罗国桢.环境本底辐射测量和剂量评价[M].北京:原子能出版社,1986.
[6]V.I.Karpov,et al,Health Physics,Vol.39(5),P819,1980.
[7]L.S.Quindos,et al,Conversion Factors for External Gamma Dose Derived from Natural Radionuclides in Soils,Journal of Environmental Radioactivity,Vol.71,P139-145,2004.
[8]L.Koblinger,Calculation of Exposure Rates from Gamma Sources in Walls of Dwelling Rooms,Health Physics,Vol.34(5),P459,1978.
[9]S.Neumaier,D.Arnold,et al,The PTB Underground Laboratory for Dosimetry and Spectrometry,Applied Radiation and Isotopes,Vol.53,P173,2000.