用户名: 密码: 验证码:
直线导轨式文物展柜水平隔震装置性能试验
详细信息    查看官网全文
摘要
为保护馆藏浮放文物,研制了一款直线导轨式文物展柜水平隔震装置。以某博物馆展柜及柜内文物为对象,制作了等比例模型。将隔震装置安装在展柜底部,采取振动台试验方法,测试了隔震装置的隔震性能,并与非隔震情况进行了对比。通过输入水平单向地震波,对比分析了隔震/非隔震条件下系统的动力特性、加速度响应特征、动力放大系数等参数。试验还讨论了隔震条件下,文物、隔震装置的位移响应特征及隔震装置的复位能力。结果表明:非隔震条件下,展柜的基频为f0=13.5Hz,文物的加速度响应随着地震波强度增大而表现明显,动力放大系数Df始终大于1,且文物在较大地震烈度作用下很容易产生倾覆现象。与之相对比,隔震系统(隔震装置+展柜+文物)基频为f=0.775Hz,阻尼比为ξ=4.5%;在不同类型、不同强度的地震波作用下,文物均能保持稳定振动状态,其位移及加速度响应始终很小,动力放大系数D均小于1;隔震装置的行程始终在容许范围内,且装置具有良好的复位能力。因此,本直线导轨式隔震装置具有很好的隔震效果。
To protect museum cultural relics against seismic damage, a linear rail type of level isolation device for museum showcase is developed. To study its isolation performances, shaking table tests are carried out. Model of showcase and replica of a ceramic cultural relics are made, the replica is set in the showcase by free-standing status. 2 conditions for the showcase boundary are considered: isolation condition- it is fixed to top of the isolation device, and the device free stands on shaking table board; non isolation condition- it is directly fixed to the shaking table board. Under level earthquakes, dynamic characteristics of the showcase are obtained; seismic responses such as acceleration, dynamic magnification coefficient and so on of the replica are discussed. Besides, under isolation condition, displacement response of both the isolation device and the replica are studied, re-centreing ability of the device is also tested. Results show that under non isolation condition, basic frequency value of the showcase is f0=13.5Hz; acceleration responses of the replica increases with the increase of input earthquake intensity, its dynamic magnification coefficient value Df is always greater than 1, and it is easy to overturn under high intensity earthquake waves. By contrast, under isolation condition, basic frequency of the system(isolation device+showcase+replica) is f=0.775 Hz, and its damping ratio is ξ=4.5%; both the replica and the showcase keep stable vibration status under different intensity of earthquake waves; dynamic magnification coefficient value of the replica is always less than 1. For the isolation devices, its maximum displacement value D is always within the permission scope, and it also has good re-centering ability. Thus the linear rail type of level isolation device has good isolation performances.
引文
[1]周乾,闫维明.汶川地震可移动文物震害研究[J].文物保护与考古科学,2010,22(3):36-43.
    [2]光明日报前方报道组.玉树地震文物损毁情况[N].光明日报,2010-04-24(006).
    [3]四川文物考古研究院.“4?20”芦山地震四川文物保护单位受损情况调查报告[J].四川文物,2013,(03):3-8.
    [4]吴来明,王忠良,高华平,等.博物馆文物的防震保护研究(一)传统抗震措施与现代隔震技术[J].文物保护与考古科学,2001,13(2):46-53.
    [5]周乾,闫维明,周锡元,等.我国博物馆陈列文物防震技术现状研究[J].灾害学,2010,25(S):201-206.
    [6]周乾,闫维明,纪金豹.馆藏浮放文物隔震装置的开发与应用[J].防灾减灾工程学报,2013,33(2):147-154.
    [7]徐起贺,陈静.滚动直线导轨副的研究现状及发展动向[J].河南机电高等专科学校学报,2009,17(2):1-3.
    [8]向宝明.SKT滚动直线导轨副的制造技术[J].金属加工(冷加工),2011,(06):20-22.
    [9]张英会,刘辉航,王德成,等.弹簧手册[M].北京:机械工业出版社,1997.
    [10]马丽慧,王海霞.干摩擦板-复位弹簧系统隔震性能研究[J].武汉理工大学学报,2010,32(9):140-144.
    [11]李雄彦,薛素铎.摩擦-碟簧三维复合隔震支座的性能试验研究[J].世界地震工程,2011,27(3):1-7.
    [12]张延庆,杨庆丽,高向宇.带有复合摩擦阻尼系统的基础隔震结构分析[J].吉林大学学报(地球科学版),2013,43(3):908-913.
    [13]黄斌,蒲武川,张海洋,等.基于超弹性SMA螺旋弹簧的基础隔震研究[J].地震工程与工程振动,2014,34(2):209-215.
    [14]ZHOU Q,YAN W M.Sliding response of free-standing cultural relics under earthquakes by simulation[J].Advanced Materials Research,2011,163-167:2142-2146.
    [15]周乾,闫维明,纪金豹.馆藏浮放陶瓷文物地震摇晃响应振动台试验[J].文物保护与考古科学,2013,25(3):48-54.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700