以火电厂循环冷却水为研究对象,以实验室自制的"双通道工业循环冷却水动态模拟实验台"为实验平台,利用高压静电离子棒对火电厂循环冷却水进行了动态模拟阻垢实验。通过对循环冷却水的极限碳酸盐硬度分析发现,实验组达到极限碳酸盐硬度的时间比对照组延迟30min,表明高压静电离子棒对火电厂循环冷却水确有阻垢效果。
The circulating cooling water in thermal power plant as the research object, using self-made "dual channel industrial circulating cooling water dynamic simulation experiment platform" for experimental platform, ion stick of circulating cooling water for thermal power plant were simulated to use the inhibition experiment by high voltage electrostatic. The ultimate carbonate hardness of the cooling water analysis, the experimental group reached the limit of time delay carbonate hardness 30 min than the control group, showing that the high voltage electrostatic ion stick which on thermal power plant circulating cooling water has inhibiting effect.
引文
[1]周本省.工业水处理技术[M].北京:化学工业出版社,2002.
    [2]刘智安.电厂水处理技术[M].北京:中国水利水电出版社,2009:4-5
    [3]高秀山,张渡.火电厂循环冷却水处理[M].北京:中国电力出版社,2002:61-63.
    [4]刘智安,赵婧,赵巨东,等.高压静电水处理腔内电场分布分析与阻垢效果研究,中国电机工程学报,2014.Vol.34.No.35:6296-6303
    [5]杨星,刘智安,龙山,等,电磁场协同处理电厂循环冷却水阻垢试验,工业水处理,2016.Vol.36.No.5:44-46
    [6]叶群实,胡胜利.离子棒静电水处理器在工业水处理中的应用[J].燃料与化工,1997.28(2):101-103.
    [7]刘金平,刘雪峰,杜艳国,等.凝汽器冷却水污垢热阻的研究[J].中国电机工程学报,2005,25(15):100-105.
    [8]Li W.The internal surface area basis,a key issue of modeling fouling in enhanced heat transfer tubes[J].International Journal of Heat and Mass Transfer 2003,46(22):4345-4349.
    [9]祁利明,赵全中,禾志强.静电离子棒处理电厂循环冷却水试验研究[J].工业用水与废水,2009,40(6):63-65.
    [10]李梅,徐锐,曲久辉.直流脉冲电磁技术的阻垢效应[J].水处理技术,2003,32(1):58-61.
    [11]刘洋.双通道工业循环冷却水动态模拟实验台的研制及阻垢实验[D].内蒙古:内蒙古工业大学,2012.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700