用户名: 密码: 验证码:
汞分析仪固体直接进样测定鹿茸中汞含量的方法研究
详细信息    查看官网全文
摘要
利用Hydra IIC型汞分析仪建立了鹿茸中汞含量的分析方法。鹿茸直接称样后,无需任何前处理,5min内即可完成汞含量的测定。该方法的线性范围0~290ng,相关系数优于0.999,检出限0.0012ng,相对标准偏差4.48%,加标回收率99.9%~116.4%。此方法具有灵敏度高、精密度好、回收率高、简单省时、无需样品前处理等优点,适用于鹿茸中汞含量的测定。
The method for Hg content analysis in the deer velvet was established by using Hydra IIC mercury analyzer.The Hg content was detected within only 5min by using deer velet directly without pretreatment.This method performs well,of which the linear range was 0 ~290ng,the correlation coefficient reached beyond 0.999,the detection limit was 0.0012 ng,the relative standard deviation was 4.48% and the recovery rate attained to 99.9%~ 116.4%.The so-established method is suitable for the analysis of Hg within deer velvet,in virtue of its advantages,such as high sensitivity,good precision,high recovery rate,time saving,pretreatment free and so on.
引文
[1]中华人民共和国药典.鹿茸[M].北京:中国医药科技出版社,2010,303-303.
    [2]中华人民共和国农业行业标准.鹿茸片NY/T 1162—2006[S].北京:中国农业出版社,2006:1-5.
    [3]中华人民共和国国家标准.食品中总砷及无机砷的测定GB/T 5009.11-2003[S].北京:中国标准出版社.2003:71-84.
    [4]孙娟,张阳,李峰.鹿茸商品药材中有害元素分析[J].辽宁中医杂志,2009,36(2):250-251.
    [5]刘佳佳,张浩,李然,等.原子吸收光谱法测定不同鹿龄梅花鹿角盘矿质元素含量[J].安徽农业科学,2010,38(5):2 121-2 122.
    [6]陈永欣,刘顺琼,黎香荣,等.汞分析仪直接测定矿石中的痕量汞[J].岩矿测试,2011,30(1):67-70.
    [7]赵雪莲,郭兴明,李童颜,等.现代仪器分析方法在煤中汞测定中的应用[J].现代化工,2010,30(8):87-91.
    [8]刘俊娓,魏静,王冠.使用AP3和DMA-80直接测汞仪测定奶粉中汞含量的方法比较[J].分析与检测,2012,9:36-37.
    [9]陈辉,林明珠.DMA80直接测汞仪测定螺旋藻粉中的总汞[J].现代预防医学,2007,34(6):1144-1149.
    [10]刘丽萍,张妮娜,李筱薇,等.直接测汞仪测定食品中的总汞[J].中国食品卫生杂志,2010,22(1):19-23.
    [11]李海峰.检出限几种常用计算方法的分析和比较[J].光谱实验室,2010,27(6):2 465-2 469.
    [12]陈国友.微波消解ICP-MS法同时测定蔬菜中14种元素[J].分析测试学报,2007,26(5):742-745.
    [13]EPA Method 7473,Mercury in solids and solutions by thermal decomposition,amalgamation,and atomic absorption spectrophotometry[S].1998.