摘要
针对我国煤矿井下高压供电系统普遍存在的漏电越级跳闸问题,在分析高压漏电保护的实现方法和电力监控系统漏电保护原理的基础上,提出了高低压电网选择性漏电保护技术。该技术可实现准确可靠的高压选择性漏电保护,给煤矿安全生产和安全供电提供了技术保障。
In response to the widespread problem of leakage across the high-voltage power supply system in coal mines, based on the analysis of the realization method of high voltage leakage protection and the principle of power leakage protection of power monitoring system, the selective leakage protection technology of high and low voltage power grid is proposed. The technology can achieve accurate and reliable high-voltage selective leakage protection, providing technical guarantee for safe production and safe power supply in coal mines.
引文
[1]李国顺,张长勇,张鹏程,刘国亭.矿井电网选择性漏电保护实用电路的研究[J].煤炭工程,2010(02):92-94.
[2]高彦,王念彬,王彦文.基于零序功率方向选择性漏电保护系统的研究[J].煤炭科学技术,2005(11):43-45+48.
[3]孙士宏.矿用低压馈电开关选择性漏电保护的研究[J].煤矿机械,2016,37(04):59-61.
[4]陈奎,唐轶.单相接地故障综合判据选线研究[J].电气应用,2007(05):30-32+41.
[5]王清亮.补偿接地电网的暂态量选线保护研究[D].西安科技大学,2010.
[6]黄锋,袁振海,庞宏宇.复小波在谐振接地系统故障选线中的应用研究[J].煤炭工程,2012(11):82-84+88.