用户名: 密码: 验证码:
热老化对植物油纸绝缘中水分平衡特性的影响研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Study on the Influences of Thermal Aging on Water Balance Characteristics in Plant Oil-paper Insulation
  • 作者:黄青丹 ; 莫文雄 ; 宋浩永
  • 英文作者:HUANG Qingdan;MO Wenxiong;SONG Haoyong;Guangzhou Power Supply Bureau Electric Power Test Research Institute;
  • 关键词:植物绝缘油 ; 油纸绝缘 ; 水分平衡
  • 英文关键词:plant insulating oil;;oil-paper insulation;;water balance
  • 中文刊名:DGJY
  • 英文刊名:Electric Engineering
  • 机构:广州供电局电力试验研究院;
  • 出版日期:2018-02-25
  • 出版单位:电工技术
  • 年:2018
  • 期:No.466
  • 基金:面向绿色电网的高压设备环保型生物绝缘油研制及示范应用(项目编号:K-GZM2013-002)
  • 语种:中文;
  • 页:DGJY201804033
  • 页数:4
  • CN:04
  • ISSN:50-1072/TM
  • 分类号:81-84
摘要
设计不同老化组合的植物油纸水分平衡试验,分别研究了植物绝缘油和绝缘纸热老化单独对水分平衡特性的影响,以及考虑换油影响的植物油纸热老化水分平衡和扩散特性,为变压器长期运行时油纸绝缘的安全可靠性提供理论和试验基础。
        The water balance test of plant oil-paper was designed with different aging combinations in this paper.The influences of thermal aging of plant insulating oil and insulation paper on water balance characteristics were studied,respectively.The moisture balance and diffusion characteristics of thermal aging of plant oil-paper affected by oil change wereinvolved,which provided theoretical and experimental basis for safety and reliability of oil-paper insulation in long-term operation of transformer.
引文
[1]Garcia B.A moisture-in-oil model for power transformer monitoring-Part II:Experimental verification[J].IEEE Transactions on Power Delivery,2005,20(2):1423-1429.
    [2]Morin A J,Ii,Zahn M,Melcher J R.Fluid electrification measurements of transformer pressboard/oil insulation in a Couette charger[J].IEEE Transactions on Electrical Insulation,1991,26(5):870-901.
    [3]Fabre J,Pichon A.Deteriorating processes and products of paper in oil[J].CIGRépaper,1960.
    [4]Emsley A M,Stevens G C.Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers[J].IEE Proceedings-Science,Measurement and Technology,1994,141(5):324-334.
    [5]Heydon R.Condition monitoring of transformer oil[C].Power Electronic Drives and Energy Systems for Industrial Growth,1998.Proceedings.1998International Conference on.IEEE,1998:249-253.
    [6]Oommen T.V.Moisture equilibrium in paper-oil insulation systems[C].Electrical/Electronical Insulation Conference,1983EIC 6th.IEEE,1983:162-166.
    [7]Shkolnik A.Determination of water content in transformer insulation[C].Dielectric Liquids,2002.ICDL 2002.Proceedings of 2002IEEE 14th International Conference on Dielectric Liquids.ICDL 2002.IEEE,2002:337-340.
    [8]Griffin P J,Bruce C M,Christie J D.Comparison of water equilibrium in silicone and mineral oil transformers[C].Minutes of the Fifty-Fifth Annual International Conference of Doble Clients,1988:10-19.
    [9]Martins M.Study of moisture equilibrium in oil-paper system with temperature variation[C].Properties and Applications of Dielectric Materials,2003.Proceedings of the 7th International Conference on.IEEE,2003:1124-1129.
    [10]杨丽君.变压器油纸绝缘老化特征量与寿命评估方法研究[D].重庆:重庆大学,2009.
    [11]Koch M,Tenbohlen S.Evolution of bubbles in oil-paper insulation influenced by material quality and ageing[J].Iet Electric Power Applications,2011,5(1):168-174.