摘要
为了改善现有污染源废气排放的采样技术,特别是颗粒物稀释采集技术上所存在的不足,如射流技术会产生伯努利效应,导致射流泵体积大、重量重、样品均匀性差,且不能实现等速采样等缺点。本研究设计开发了一套可适用于不同污染源的、模块化自动化控制的、轻便性、均匀性好的采样装置。该装置可模拟污染源的高温废气排放到大气中的冷却、稀释、凝结等反应过程。采用装置设计成四通道均匀采样,使其可作为大气污染物的源谱解析研究的专用采样设备,同时也可作为其他精密分析仪器的预处理装置。
        In this paper,a set of sampling device was designed and developed in order to overcome the shortcoming of the dilution tunnel sampling for particles,including the Bernoulli effect of the jet,the large and heavy jet pump,the poor uniformity,etc.The new sampling device,which is suitable for the different pollution sources,has the advantages of modularization,automatic control,portability and good uniformity.The process of the cooling,dilution and transportation of the high-temperature emissions into the atmosphere can be simulated.A special sampler for the study of the source spectrum analysis for air pollutants is provided due to the four-channel design,and it can be also adopted as a pretreatment device for the other high-precision analyzers.
引文
[1]孔少飞,白志鹏,陆炳,等.固定源排放颗粒物采样方法的研究进展[J].环境科学与技术,2011,34(12):88-94.
    [2]陈魁,白志鹏,朱坦,郭光焕.颗粒物再悬浮采样器采样均匀度研究[J].过程工程学报,2004,4(增刊):864-867.
    [3]ISO 25597.2013Stationary source emissions-Test method for determining PM2.5and PM10mass in stack gases using cyclone samplers and sample dilution[S].
    [4]US EPA.Method 201-Determentation of PM10 Emissions(Exhaust Gas Recycle Procedure[S].
    [5]US EPA.Method 201A-Determentation of PM10Emissions[S].
    [6]US EPA.Method 202-Determentation of Condensable Particulate Emissions from Stationary Sources[S].
    [7]钟琪,王文,王哲,陈文亮.新型大气颗粒物自动换膜采样装置研究[J].电子测量与仪器学报,2018,32(4):7-12.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700