摘要
集成电路制造技术的发展使单芯片集成多谱段红外探测器成为可能,其中长线列红外探测器读出电路设计遇到的挑战之一就是寄生效应。针对一款多谱段长线列用读出电路在最小积分电容时行间输出电平差异显著,导致成像出现明暗条纹的现象进行了测试分析,得出复杂的电路版图寄生效应是主要原因。通过优化设计及流片验证,解决了寄生效应导致的成像明暗条纹问题。
With the development of integrated circuit manufacture,it is possible to integrate multispectral linear array infrared detector on one chip. One of the major challenges is parasitic effects in ROIC design for long linear array.This paper analysed an ROIC design for multispectral long linear array which encountered obvious difference for ultra-small integrate capacitor between consecutive line output while the input unchanged,which results in bright-dark line in an image. Thorough testing and analyzing,the cause was found due to the parasitic effects of the complicated circuit layout. A more robust layout design was taped out and the problem was resolved.
引文
[1]C B Pease.Satellite imaging instruments[M].England:Ellis Horwood Limited,1991.
[2]J Rienstra.M ballard multispectral focal plane assembly for satellite remote sensing[C].Aerospace Conference1998,5:233-241.
[3]Michael Dahlin.Advanced focal plane array systems for next-generation scanning remote sensing instrument[J].Proc.SPIE,2003,4820:406-417.
[4]许洪,王向军.多光谱、超光谱成像技术在军事上的应用[C].2006年全国光电技术学术交流会会议论文集,2006:41-46.
[5]Ashok Sood,James Egerton,et al.Design considerations of ROIC for single color LWIR and multicolor IR focal plane arrays[J].Proc.of SPIE,2006,6294:62940A.
[6]董在望,李冬梅,王志华,等.高等模拟集成电路[M].北京:清华大学出版社,2006:206.