用户名: 密码: 验证码:
核电厂安全级高可靠主控制器设计技术研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Design Technology for Highly Reliable Main Controller of Security Level in Nuclear Power Plants
  • 作者:马权 ; 罗琦 ; 宋小明 ; 刘艳阳
  • 英文作者:Ma Quan;Luo Qi;Song Xiaoming;Liu Yanyang;Science and Technology on Reactor System Design Technology Laboratory,Nuclear Power Institute of China;
  • 关键词:主控制器 ; 诊断 ; 热备 ; 通信 ; 数字化仪控系统(DCS)
  • 英文关键词:Main controller;;Diagnosis;;Hot standby;;Communication;;Digital control system(DCS)
  • 中文刊名:HDLG
  • 英文刊名:Nuclear Power Engineering
  • 机构:中国核动力研究设计院核反应堆系统设计技术重点实验室;
  • 出版日期:2019-04-23 17:15
  • 出版单位:核动力工程
  • 年:2019
  • 期:v.40;No.234
  • 语种:中文;
  • 页:HDLG201903017
  • 页数:6
  • CN:03
  • ISSN:51-1158/TL
  • 分类号:85-90
摘要
从安全级数字化仪控系统(DCS)平台主控制器的功能特点、设备特点以及应用特点出发,结合相关法律法规及标准要求,对高可靠主控制器设计的诊断、冗余、通信、嵌入式软件开发等关键技术进行了研究,并将其应用于中国核工业集团有限公司安全级DCS平台——龙鳞系统(NASPIC)的主控模块设计中,同时搭建了华龙一号模拟件,并以停堆、专设、定期试验等典型样例对模拟件进行了功能测试和性能测试,这些测试和核安全局鉴定试验的结果表明,诊断覆盖率达到98%,超出标准要求;实测通信误码率小于10-11,达到甚至超过其他主流厂家安全级DCS产品指标;热备冗余架构、嵌入式软件均满足1E级设备要求,实现了主控制器的高可靠性。
        Considering the characteristics of the main controller of the digital control system(DCS) platform of security level and its function and application, based on the specifications in relevant laws, regulations and standards, studies had been conducted on the diagnosis, redundancy, communication and embedded design of the highly reliable main controller. Key technologies such as software development were studied and applied in the design of the main control module of the China National Nuclear Corporation's DCS platform of security level, the Nuclear Advanced Safety Platform of I&C(NASPIC). At the same time, the HPR1000 simulation platform was built and its functions and performance were tested in the shutdown function test, engineering safety facility actuation function test and periodic tests. These tests and the qualification test conducted by the National Nuclear Safety Administration showed that the diagnostic coverage rate reached 98%, exceeding the standard requirements; the measured communication error rate was less than 10-11, meeting or even exceeding the security level DCS product specifications of other manufacturers; the hot standby redundancy architecture and embedded software meet the requirements of Class1 E equipment, ensuring the high reliability of the main controller.
引文
[1]李静霞,于劲松.核电站安全级DCS缺陷危害性分级的研究与应用[J].自动化博览,2015,3:64-67.
    [2]International Electrotechnical Commission.Functional safety of electrical/electronic/programmable electronic safety-related systems Part 2:Requirements for electrical/electronic/programmable electronic safetyrelated systems:IEC 61508-2[S].2010.
    [3]The Institute of Electrical and Electronics Engineers.Inc.IEEE standard criteria for digital computers in safety systems of nuclear power generating stations:IEEE Std 7-4.3.2[S].2003.
    [4]International Electrotechnical Commission.Nuclear po-wer plants-Instrumentation and control systems important to safety-Software aspects for computer-based systems performing category Afunctions:IEC 60880[S].2006.
    [5]钱卢振.试论通信信号处理中过采样技术的实践应用[J].科技视界,2017,33:169-169.
    [6]高明.基于双机热备结构的嵌入式ARM容错控制系统[J].计算机测量与控制,2013,21(7):1828-1830.
    [7]孟邹清.如何理解和分析功能安全技术中的诊断覆盖率[J].仪器仪表标准化与计量,2009,2:24-26.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700