摘要
对比了大型火电机组中辅机设备冷却水系统采用填料喷雾冷却塔与无填料喷雾冷却塔的技术特点,介绍了无填料喷雾冷却塔的工作原理,并对其节能效益进行了计算。结果表明:与传统型填料喷雾冷却塔相比,采用无填料喷雾冷却塔较大地降低了设备运行维护费用,提高了设备运行的可靠性。
A comparative analysis was conducted on technical features of packing and no-packing spray cooling tower commonly adopted for auxiliary facilities of large thermal power units, while an introduction was made to the working principle of no-packing spray cooling tower, together with a calculation on its energy-saving effectiveness. Results show that, compared with traditional packing spray cooling tower, the application of no-packing spray cooling tower could reduce the operation and maintenance cost, and improve the operation reliability of relevant facilities simultaneously.
引文
[1] 薛志峰.公共建筑节能[M].北京:中国建筑工业出版社,2007.
[2] 倪季良.冷却塔的落水噪声及防治措施的探讨[J].电力建设,2003,24(3):15-18.
[3] 赵振国,石金玲,周常虹,等.冷却塔雨区的热力特性[J].水利学报,2000,31(3):12-18.
[4] 赵顺安.山西阳城电厂三号冷却塔测试报告[R].北京:中国水利水电科学研究院,2002.
[5] 赵顺安,廖内平,徐铭.逆流式自然通风冷却塔二维数值模拟优化设计[J].水利学报,2003,34(10):26-31,37.
[6] 丁广城,陈颖.地源热泵冷却塔联合运行的技术经济分析[C]//中国制冷学会2007学术年会论文集.北京:中国制冷学会,2007.
[7] 刘官郡.横流式自然通风冷却塔设计[J].工业用水与废水,2006,37(增刊1):9-20.