用户名: 密码: 验证码:
Impact of Dipole Spacing in Electrical Landfill Leakage Detection
详细信息   
摘要

 


    
    

The
    dipole spacing could affect the detection sensitivity and accuracy in the
    electrical landfill leakage detection. Based on the principle of electrical
    method, the influence of dipole spacing was analyzed and validated by experiment.
    The theoretical and experimental results show that: 1) the greater the dipole
    spacing is, the higher the detection sensitivity is, but the locating accuracy
    lower and some leaks will easily be undetected; and 2) the smaller the dipole
    spacing is, the higher the leak locating accuracy is, but the detection
    sensitivity lower. In engineering practice, the dipole spacing usually is
    determined as 1 m.


    
    

 